Rectangular parcel and constant section
Check a 60 by 40 m parcel and a constant-area roadway section.
More examplesSurvey anatomy
Parcel & roadway cross sections
Computed results
Areas agree
Boundary geometry
- Shoelace area
- 2,400m²
- Square feet
- 25,833.385ft²
- Acres
- 0.59305ac
- Hectares
- 0.24ha
- DMD area
- 2,400m²
- Perimeter
- 200m
- Point order
- Counterclockwise
Roadway volumes
- Average end area
- 600m³
- Average end area
- 784.77037yd³
- Prismoidal volume
- 600m³
- Prismoidal volume
- 784.77037yd³
- Correction Cₚ
- 0m³
- Correction Cₚ
- 0yd³
Boundary courses and DMD
| Leg | Start Nm | Start Em | ΔNm | ΔEm | DMDm | DMD × ΔNm² |
|---|---|---|---|---|---|---|
| 1 | 0 | 0 | 0 | 60 | 60 | 0 |
| 2 | 0 | 60 | 40 | 0 | 120 | 4,800 |
| 3 | 40 | 60 | 0 | −60 | 60 | 0 |
| 4 | 40 | 0 | −40 | 0 | 0 | −0 |
Worked check
The enclosed area is 2,400 m² and the perimeter is 200 m. A constant 20 m² section integrated over 30 m gives 600 m³ by either volume method.
- Shoelace area (m²)
- 2,400
- DMD area (m²)
- 2,400
- Perimeter (m)
- 200
- Prismoidal volume (m³)
- 600
These checks describe the original example. Reset restores the original inputs.
Formulas and conventions
Compute plane-coordinate area
Signed double area = Σ(EᵢNᵢ₊₁ − Eᵢ₊₁Nᵢ)
Use three to eight distinct corners in perimeter order. The perimeter sums straight edges. The absolute half-sum is enclosed area. Positive signed area corresponds to counterclockwise order in a north-up plan.
Cross-check by DMD
DMD₁ = ΔE₁ · DMDᵢ = DMDᵢ₋₁ + ΔEᵢ₋₁ + ΔEᵢ · Area = |Σ(DMDᵢΔNᵢ)| ÷ 2
Both methods translate to a local origin before calculation. Acres use the International-foot definition; square U.S. survey feet are also reported when that working unit is selected.
Compare two roadway section volumes
AEA = L(A₁ + A₂) ÷ 2 · V = L(A₁ + 4Aₘ + A₂) ÷ 6 · Cₚ = AEA − V
Take Aₘ at the true midpoint. The prismoidal formula is exact for a prismoid and for a quadratic cross-section area profile. Compare like cut or fill areas. Positive Cₚ means average end area overstates the prismoidal volume.
More worked examples
Open a case to edit its inputs and compare the original checks.
- Triangular parcel and roadway wedge
Compute a right-triangle parcel and check a linearly changing end area.
- Concave woodlot and broad midsection
Subtract a triangular notch and check a negative prismoidal correction.
- Clockwise legacy survey-foot parcel
Check a clockwise 43,560 ftUS² enclosure and volume conversion from survey-foot sections.
- Eight corners at large grid coordinates
Check a chamfered block without losing precision to large coordinate offsets.
- Positive prismoidal correction in a roadway reach
Compare unequal end areas with a midsection smaller than their average.
GeoSurveyLab · Field calculation
Rectangular parcel and constant section
Areas agree
Field inputs
- Working unit
- Meters (m)
- Number of corners
- 4
- Boundary coordinates 1
- 0 / 0
- Boundary coordinates 2
- 0 / 60
- Boundary coordinates 3
- 40 / 60
- Boundary coordinates 4
- 40 / 0
- Station separation
- 30 m
- First section A₁
- 20 m²
- Midsection Aₘ
- 20 m²
- Last section A₂
- 20 m²
Boundary geometry
- Shoelace area
- 2,400m²
- Square feet
- 25,833.385ft²
- Acres
- 0.5931ac
- Hectares
- 0.24ha
- DMD area
- 2,400m²
- Perimeter
- 200m
- Point order
- Counterclockwise
Roadway volumes
- Average end area
- 600m³
- Average end area
- 784.7704yd³
- Prismoidal volume
- 600m³
- Prismoidal volume
- 784.7704yd³
- Correction Cₚ
- 0m³
- Correction Cₚ
- 0yd³
Boundary courses and DMD
| Leg | Start Nm | Start Em | ΔNm | ΔEm | DMDm | DMD × ΔNm² |
|---|---|---|---|---|---|---|
| 1 | 0 | 0 | 0 | 60 | 60 | 0 |
| 2 | 0 | 60 | 40 | 0 | 120 | 4,800 |
| 3 | 40 | 60 | 0 | −60 | 60 | 0 |
| 4 | 40 | 0 | −40 | 0 | 0 | −0 |
For planning, training, and independent checks. Have a locally licensed Professional Land Surveyor (PLS) verify legal boundaries and survey control. Have a licensed Professional Engineer (PE) verify engineering layout and design where required.