Vertical zenith shot in U.S. survey feet
Confirm that a pure vertical shot has zero horizontal distance and zero curvature correction.
More examplesSurvey anatomy
Sightline & vertical reduction
Computed results
Within limit
Slope reduction
- Raw slope distance
- 30ftUS
- Scaled slope distance
- 30ftUS
- Vertical angle
- 90°
- Zenith angle
- 0°
- Horizontal distance
- 0ftUS
- Axis-to-prism ΔZ
- 30ftUS
Ground elevation
- Occupied point
- 120ftUS
- Curvature / refraction
- 0ftUS
- Ground-to-ground ΔZ
- 29ftUS
- Target point
- 149ftUS
- C/R review limit
- 0.16404ftUS
Worked check
A zenith angle of zero points straight up. From 120 ftUS, add the 30 ftUS vertical component and subtract the 1 ftUS height difference.
- Horizontal distance (ftUS)
- 0
- Curvature and refraction (ftUS)
- 0
- Target elevation (ftUS)
- 149
These checks describe the original example. Reset restores the original inputs.
Formulas and conventions
Scale and resolve the shot
S corrected = S(1 + ppm ÷ 10⁶) · HD = S corrected cos(v) · VD = S corrected sin(v)
Vertical angle v is positive above level. For a zenith reading Z, v = 90° − Z. Set ppm to zero for a distance the instrument already corrected.
Apply curvature and refraction once
C/R = +0.0675K² m · equivalently ≈ +0.0206M² ft
K is horizontal distance in kilometers. M is horizontal distance in thousands of feet. The calculator evaluates the metric expression and converts the result to preserve a consistent correction across units. Use Off / already applied if the instrument has made this correction.
Compute the ground-to-ground change
ΔZ = HI + VD + C/R − HT · Target elevation = occupied elevation + ΔZ
The review limit flags when the correction itself is larger than your chosen value. The approximation models standard refraction. Actual refraction varies with the air path, especially near the ground.
More worked examples
Open a case to edit its inputs and compare the original checks.
- One-kilometer level sightline
Isolate the combined curvature and refraction correction on a level shot.
- A 30° uphill vertical angle
Resolve a 200 m slope shot and account for unequal instrument and prism heights.
- A descending shot at zenith 120°
Use a zenith angle greater than 90° to compute a negative vertical component.
- A +20 ppm atmospheric distance scale
Apply a measured atmospheric scale correction to a raw 1,500 m slope distance.
- Curvature correction at 1,000 ft
Relate the customary coefficient in feet to the unit-consistent metric expression.
GeoSurveyLab · Field calculation
Vertical zenith shot in U.S. survey feet
Within limit
Field inputs
- Working unit
- U.S. survey foot (ftUS)
- Slope distance
- 30 ftUS
- EDM scale correction
- 0 ppm
- Angle reference
- Zenith angle
- Observed angle
- 0 °
- Instrument height HI
- 5 ftUS
- Prism height HT
- 6 ftUS
- Occupied elevation
- 120 ftUS
- Correction
- Apply to raw shot
- Correction review limit
- 0.1640416666666667 ftUS
Slope reduction
- Raw slope distance
- 30ftUS
- Scaled slope distance
- 30ftUS
- Vertical angle
- 90°
- Zenith angle
- 0°
- Horizontal distance
- 0ftUS
- Axis-to-prism ΔZ
- 30ftUS
Ground elevation
- Occupied point
- 120ftUS
- Curvature / refraction
- 0ftUS
- Ground-to-ground ΔZ
- 29ftUS
- Target point
- 149ftUS
- C/R review limit
- 0.164ftUS
For planning, training, and independent checks. Have a locally licensed Professional Land Surveyor (PLS) verify legal boundaries and survey control. Have a licensed Professional Engineer (PE) verify engineering layout and design where required.