A +20 ppm atmospheric distance scale

Apply a measured atmospheric scale correction to a raw 1,500 m slope distance.

More examples

Field inputs

Switching the unit converts the inputs.

Total station shot
Curvature and refraction

Use zero ppm for a distance already scaled by the instrument. Zenith is 0° straight up. Vertical angles are signed from level.

Survey anatomy

Sightline & vertical reduction

Edit inputs
Sightline & vertical reductionLive plot with four readings and a check bar. C/R review limit. Correction off.HORIZONTAL1,500.03mGROUND ΔZ0mC/R ADDED0mTARGET ELEV.320mOCCUPIEDTARGETSIGHTLINEC/R OFFC/R review limitCorrection off
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Correction off

Slope reduction

Raw slope distance
1,500m
Scaled slope distance
1,500.03m
Vertical angle
0°
Zenith angle
90°
Horizontal distance
1,500.03m
Axis-to-prism ΔZ
0m

Ground elevation

Occupied point
320m
Curvature / refraction
0m
Ground-to-ground ΔZ
0m
Target point
320m
C/R review limit
0.05m

Worked check

Twenty parts per million add 0.030 m across 1,500 m. A horizontal sightline and equal instrument heights leave the target at the occupied elevation.

Corrected slope distance (m)
1,500.03
Horizontal distance (m)
1,500.03
Target elevation (m)
320

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Scale and resolve the shot

S corrected = S(1 + ppm ÷ 10⁶) · HD = S corrected cos(v) · VD = S corrected sin(v)

Vertical angle v is positive above level. For a zenith reading Z, v = 90° − Z. Set ppm to zero for a distance the instrument already corrected.

Apply curvature and refraction once

C/R = +0.0675K² m · equivalently ≈ +0.0206M² ft

K is horizontal distance in kilometers. M is horizontal distance in thousands of feet. The calculator evaluates the metric expression and converts the result to preserve a consistent correction across units. Use Off / already applied if the instrument has made this correction.

Compute the ground-to-ground change

ΔZ = HI + VD + C/R − HT · Target elevation = occupied elevation + ΔZ

The review limit flags when the correction itself is larger than your chosen value. The approximation models standard refraction. Actual refraction varies with the air path, especially near the ground.