Vertical curve calculator

Plot equal- or unequal-tangent crest and sag curves, find the turning point, and screen stopping sight distance.

Worked examples

Field inputs

Switching the unit converts the inputs.

Tangent grades
Stopping sight distance

Enter the stopping sight distance adopted for the project. A positive grade rises in increasing station order.

Survey anatomy

Profile & sight-distance check

Edit inputs
Profile & sight-distance checkLive plot with four readings and a check bar. SSD geometry. Meets geometry.PROFILECrestK RATE75ft/%CURVE LENGTH420ftSSD MIN. L334.5892ftTANGENT GRADESHIGH POINTPVCPVIPVTSSD geometryMeets geometry
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Meets geometry

Tangent and curve controls

PVC
22+40.000ft
PVC elevation
611.48ft
PVI
24+50.000ft
PVI tangent elevation
618.2ft
PVT
26+60.000ft
PVT elevation
613.16ft
Grade difference A
−5.6%
K rate
75ft/%
High point station
24+80.000ft
High point elevation
615.32ft
Turning point grade
0%

Stopping sight distance check

Required sight distance S
360ft
Geometric minimum L
334.58919ft
Geometric minimum K
59.74807ft/%
Long-curve K at S
60.04724ft/%
Sizing branch
S > L

Profile elevations and grades

PointStationftOffset from PVCftElevationftGrade%
PVC22+40.0000611.483.2
Stake22+50.00010611.793333.06667
Stake23+00.00060613.162.4
Stake23+50.000110614.193331.73333
Stake24+00.000160614.893331.06667
Stake24+50.000210615.260.4
High point24+80.000240615.320
Stake25+00.000260615.29333−0.26667
Stake25+50.000310614.99333−0.93333
Stake26+00.000360614.36−1.6
Stake26+50.000410613.39333−2.26667
PVT26+60.000420613.16−2.4

Formulas and conventions

Build the symmetric profile

A = g₂ − g₁ · z(x) = zPVC + g₁x ÷ 100 + Ax² ÷ (200L)

PVC and PVT are L/2 either side of the tangent intersection PVI. Grades are entered in percent. When grades have opposite signs, x = −g₁L/A is the interior turning point and its slope is exactly zero.

Join unequal tangents

gⱼ = (L₁g₁ + L₂g₂) ÷ L · zⱼ = zPVI + A L₁ L₂ ÷ (200L)

L₁ is PVC to PVI and L₂ is PVI to PVT. Each parabola integrates a linear grade between the endpoint and common join grade. Find the zero grade on the piece where the signs change. The local K values are L₁/|gⱼ − g₁| and L₂/|g₂ − gⱼ|.

Calculate the curvature rate

K = L ÷ |A|

K is length per percentage point of grade change. Equal grades form a straight tangent and have no finite K. Station labels use 100-foot stations or kilometer plus meters, depending on the working unit.

Compare the SSD geometry

Lmin = |A| S² ÷ C when Lmin ≥ S · otherwise max(0, 2S − C ÷ |A|)

For a crest, C = 200(√h₁ + √h₂)², with eye height 3.5 ft and object height 2 ft. For a sag, C = 200(h + S tan 1°), with headlight height 2 ft. The two minimum-length branches apply to equal tangents. Unequal tangents use a sufficient screen: both local K values must meet S²/C. If either is tighter, check the complete sight line. Use the adopted agency criteria and drainage controls.

Worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.