Short-curve stopping sight distance
Apply the short-curve branch when the required sight distance exceeds the curve length.
More examplesSurvey anatomy
Profile & sight-distance check
Computed results
Below minimum
Tangent and curve controls
- PVC
- 16+65.000ft
- PVC elevation
- 417.3ft
- PVI
- 18+00.000ft
- PVI tangent elevation
- 420ft
- PVT
- 19+35.000ft
- PVT elevation
- 417.3ft
- Grade difference A
- −4%
- K rate
- 67.5ft/%
- High point station
- 18+00.000ft
- High point elevation
- 418.65ft
- Turning point grade
- 0%
Stopping sight distance check
- Required sight distance S
- 425ft
- Geometric minimum L
- 310.42487ft
- Geometric minimum K
- 77.60622ft/%
- Long-curve K at S
- 83.68853ft/%
- Sizing branch
- S > L
Profile elevations and grades
| Point | Stationft | Offset from PVCft | Elevationft | Grade% |
|---|---|---|---|---|
| PVC | 16+65.000 | 0 | 417.3 | 2 |
| Stake | 17+00.000 | 35 | 417.90926 | 1.48148 |
| Stake | 17+50.000 | 85 | 418.46481 | 0.74074 |
| High point | 18+00.000 | 135 | 418.65 | 0 |
| Stake | 18+50.000 | 185 | 418.46481 | −0.74074 |
| Stake | 19+00.000 | 235 | 417.90926 | −1.48148 |
| PVT | 19+35.000 | 270 | 417.3 | −2 |
Worked check
With 4 percentage points of grade change, the short-curve expression 2S − C/|A| gives roughly 310 ft. Compare that length with 270 ft.
- SSD geometry branch
- S > L
- Required curve length (ft)
- 310.4248689
- Meets geometric SSD check
- No
These checks describe the original example. Reset restores the original inputs.
Formulas and conventions
Build the symmetric profile
A = g₂ − g₁ · z(x) = zPVC + g₁x ÷ 100 + Ax² ÷ (200L)
PVC and PVT are L/2 either side of the tangent intersection PVI. Grades are entered in percent. When grades have opposite signs, x = −g₁L/A is the interior turning point and its slope is exactly zero.
Join unequal tangents
gⱼ = (L₁g₁ + L₂g₂) ÷ L · zⱼ = zPVI + A L₁ L₂ ÷ (200L)
L₁ is PVC to PVI and L₂ is PVI to PVT. Each parabola integrates a linear grade between the endpoint and common join grade. Find the zero grade on the piece where the signs change. The local K values are L₁/|gⱼ − g₁| and L₂/|g₂ − gⱼ|.
Calculate the curvature rate
K = L ÷ |A|
K is length per percentage point of grade change. Equal grades form a straight tangent and have no finite K. Station labels use 100-foot stations or kilometer plus meters, depending on the working unit.
Compare the SSD geometry
Lmin = |A| S² ÷ C when Lmin ≥ S · otherwise max(0, 2S − C ÷ |A|)
For a crest, C = 200(√h₁ + √h₂)², with eye height 3.5 ft and object height 2 ft. For a sag, C = 200(h + S tan 1°), with headlight height 2 ft. The two minimum-length branches apply to equal tangents. Unequal tangents use a sufficient screen: both local K values must meet S²/C. If either is tighter, check the complete sight line. Use the adopted agency criteria and drainage controls.
More worked examples
Open a case to edit its inputs and compare the original checks.
- Symmetric metric crest high point
Solve a symmetric 2% to −2% crest and check the high point at midcurve.
- Symmetric −3% to +3% sag
Find the low point and compare its curvature rate with a required sight distance.
- Rising crest without a high point inside
Distinguish a crest in grade change from a crest with an interior summit.
- Equal grades give a straight tangent
Check elevation stationing when both grades are the same.
- Asymmetric sag in U.S. survey feet
Locate the low point of a −4% to +2% sag with unequal tangent lengths on an older alignment.
GeoSurveyLab · Field calculation
Short-curve stopping sight distance
Below minimum
Field inputs
- Working unit
- International foot (ft)
- Tangent lengths
- Equal tangent lengths
- Entering grade g₁
- 2 %
- Exiting grade g₂
- -2 %
- PVI station
- 18+00 ft
- PVI elevation
- 420 ft
- Curve length
- 270 ft
- Stake interval
- 50 ft
- Required sight distance
- 425 ft
Tangent and curve controls
- PVC
- 16+65.000ft
- PVC elevation
- 417.3ft
- PVI
- 18+00.000ft
- PVI tangent elevation
- 420ft
- PVT
- 19+35.000ft
- PVT elevation
- 417.3ft
- Grade difference A
- −4%
- K rate
- 67.5ft/%
- High point station
- 18+00.000ft
- High point elevation
- 418.65ft
- Turning point grade
- 0%
Stopping sight distance check
- Required sight distance S
- 425ft
- Geometric minimum L
- 310.4249ft
- Geometric minimum K
- 77.6062ft/%
- Long-curve K at S
- 83.6885ft/%
- Sizing branch
- S > L
Profile elevations and grades
| Point | Stationft | Offset from PVCft | Elevationft | Grade% |
|---|---|---|---|---|
| PVC | 16+65.000 | 0 | 417.3 | 2 |
| Stake | 17+00.000 | 35 | 417.9093 | 1.4815 |
| Stake | 17+50.000 | 85 | 418.4648 | 0.7407 |
| High point | 18+00.000 | 135 | 418.65 | 0 |
| Stake | 18+50.000 | 185 | 418.4648 | −0.7407 |
| Stake | 19+00.000 | 235 | 417.9093 | −1.4815 |
| PVT | 19+35.000 | 270 | 417.3 | −2 |
For planning, training, and independent checks. Have a locally licensed Professional Land Surveyor (PLS) verify legal boundaries and survey control. Have a licensed Professional Engineer (PE) verify engineering layout and design where required.