Rising crest without a high point inside

Distinguish a crest in grade change from a crest with an interior summit.

More examples

Field inputs

Switching the unit converts the inputs.

Tangent grades
Stopping sight distance

Enter the stopping sight distance adopted for the project. A positive grade rises in increasing station order.

Survey anatomy

Profile & sight-distance check

Edit inputs
Profile & sight-distance checkLive plot with four readings and a check bar. SSD geometry. Meets geometry.PROFILECrestK RATE100m/%CURVE LENGTH300mSSD MIN. L0mTANGENT GRADESNO INTERIOR TURNPVCPVIPVTSSD geometryMeets geometry
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Meets geometry

Tangent and curve controls

PVC
0+750.000m
PVC elevation
74m
PVI
0+900.000m
PVI tangent elevation
80m
PVT
1+050.000m
PVT elevation
81.5m
Grade difference A
−3%
K rate
100m/%
Interior turning point
None

Stopping sight distance check

Required sight distance S
100m
Geometric minimum L
0m
Geometric minimum K
0m/%
Long-curve K at S
15.20103m/%
Sizing branch
S > L

Profile elevations and grades

PointStationmOffset from PVCmElevationmGrade%
PVC0+750.0000744
Stake0+800.0005075.8753.5
Stake0+850.00010077.53
Stake0+900.00015078.8752.5
Stake0+950.000200802
Stake1+000.00025080.8751.5
PVT1+050.00030081.51

Worked check

The grade is always positive and decreases from 4% to 1%. The curve is crest-shaped with no zero-grade point between PVC and PVT.

Profile type
Crest
Interior turning point
Undefined
PVC elevation (m)
74
PVT elevation (m)
81.5

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Build the symmetric profile

A = g₂ − g₁ · z(x) = zPVC + g₁x ÷ 100 + Ax² ÷ (200L)

PVC and PVT are L/2 either side of the tangent intersection PVI. Grades are entered in percent. When grades have opposite signs, x = −g₁L/A is the interior turning point and its slope is exactly zero.

Join unequal tangents

gⱼ = (L₁g₁ + L₂g₂) ÷ L · zⱼ = zPVI + A L₁ L₂ ÷ (200L)

L₁ is PVC to PVI and L₂ is PVI to PVT. Each parabola integrates a linear grade between the endpoint and common join grade. Find the zero grade on the piece where the signs change. The local K values are L₁/|gⱼ − g₁| and L₂/|g₂ − gⱼ|.

Calculate the curvature rate

K = L ÷ |A|

K is length per percentage point of grade change. Equal grades form a straight tangent and have no finite K. Station labels use 100-foot stations or kilometer plus meters, depending on the working unit.

Compare the SSD geometry

Lmin = |A| S² ÷ C when Lmin ≥ S · otherwise max(0, 2S − C ÷ |A|)

For a crest, C = 200(√h₁ + √h₂)², with eye height 3.5 ft and object height 2 ft. For a sag, C = 200(h + S tan 1°), with headlight height 2 ft. The two minimum-length branches apply to equal tangents. Unequal tangents use a sufficient screen: both local K values must meet S²/C. If either is tighter, check the complete sight line. Use the adopted agency criteria and drainage controls.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.