Short-curve stopping sight distance

Apply the short-curve branch when the required sight distance exceeds the curve length.

More examples

Field inputs

Switching the unit converts the inputs.

Tangent grades
Stopping sight distance

Enter the stopping sight distance adopted for the project. A positive grade rises in increasing station order.

Survey anatomy

Profile & sight-distance check

Edit inputs
Profile & sight-distance checkLive plot with four readings and a check bar. SSD geometry. Below minimum.PROFILECrestK RATE67.5ft/%CURVE LENGTH270ftSSD MIN. L310.4249ftTANGENT GRADESHIGH POINTPVCPVIPVTSSD geometryBelow minimum
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Below minimum

Tangent and curve controls

PVC
16+65.000ft
PVC elevation
417.3ft
PVI
18+00.000ft
PVI tangent elevation
420ft
PVT
19+35.000ft
PVT elevation
417.3ft
Grade difference A
−4%
K rate
67.5ft/%
High point station
18+00.000ft
High point elevation
418.65ft
Turning point grade
0%

Stopping sight distance check

Required sight distance S
425ft
Geometric minimum L
310.42487ft
Geometric minimum K
77.60622ft/%
Long-curve K at S
83.68853ft/%
Sizing branch
S > L

Profile elevations and grades

PointStationftOffset from PVCftElevationftGrade%
PVC16+65.0000417.32
Stake17+00.00035417.909261.48148
Stake17+50.00085418.464810.74074
High point18+00.000135418.650
Stake18+50.000185418.46481−0.74074
Stake19+00.000235417.90926−1.48148
PVT19+35.000270417.3−2

Worked check

With 4 percentage points of grade change, the short-curve expression 2S − C/|A| gives roughly 310 ft. Compare that length with 270 ft.

SSD geometry branch
S > L
Required curve length (ft)
310.4248689
Meets geometric SSD check
No

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Build the symmetric profile

A = g₂ − g₁ · z(x) = zPVC + g₁x ÷ 100 + Ax² ÷ (200L)

PVC and PVT are L/2 either side of the tangent intersection PVI. Grades are entered in percent. When grades have opposite signs, x = −g₁L/A is the interior turning point and its slope is exactly zero.

Join unequal tangents

gⱼ = (L₁g₁ + L₂g₂) ÷ L · zⱼ = zPVI + A L₁ L₂ ÷ (200L)

L₁ is PVC to PVI and L₂ is PVI to PVT. Each parabola integrates a linear grade between the endpoint and common join grade. Find the zero grade on the piece where the signs change. The local K values are L₁/|gⱼ − g₁| and L₂/|g₂ − gⱼ|.

Calculate the curvature rate

K = L ÷ |A|

K is length per percentage point of grade change. Equal grades form a straight tangent and have no finite K. Station labels use 100-foot stations or kilometer plus meters, depending on the working unit.

Compare the SSD geometry

Lmin = |A| S² ÷ C when Lmin ≥ S · otherwise max(0, 2S − C ÷ |A|)

For a crest, C = 200(√h₁ + √h₂)², with eye height 3.5 ft and object height 2 ft. For a sag, C = 200(h + S tan 1°), with headlight height 2 ft. The two minimum-length branches apply to equal tangents. Unequal tangents use a sufficient screen: both local K values must meet S²/C. If either is tighter, check the complete sight line. Use the adopted agency criteria and drainage controls.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.