Seepage & exit gradient

Compute Darcy discharge, pore velocity, flow-net discharge and the upward exit-gradient screen.

Darcy flow
1.05e-4 m³/s
Pore velocity
6.73e-5 m/s
Exit gradient
0.292
Exit F.S.
3.49
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 2.8 m4 channels / 12 dropsExit F.S. / 33.49
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient meets the entered safety-factor target.

Calculation details
Average Darcy gradient ΔH/L0.35
Darcy velocity2.62e-5 m/s
Porosity from exit soil void ratio39 %
Flow-net discharge per unit width7.00e-5 m²/s
Head loss per potential drop0.233 m
Critical upward gradient1.018
Target maximum exit gradient0.339

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.

Worked examples