Worked example

Low-conductivity silt seepage

A silty layer transmits a small steady discharge under a sustained head difference.

Darcy flow
2.45e-7 m³/s
Pore velocity
1.59e-7 m/s
Exit gradient
0.227
Exit F.S.
4.02
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 1.8 m3 channels / 11 dropsExit F.S. / 34.02
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient meets the entered safety-factor target.

Calculation details
Average Darcy gradient ΔH/L0.3273
Darcy velocity7.20e-8 m/s
Porosity from exit soil void ratio45.4 %
Flow-net discharge per unit width1.08e-7 m²/s
Head loss per potential drop0.164 m
Critical upward gradient0.913
Target maximum exit gradient0.304

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Conductivity strongly affects flow and velocity. The geometric hydraulic gradient follows the head and path length.

  1. Divide 1.8 m by 5.5 m for i = 0.3273. Multiply ki by the section area to get Q = 2.45e-7 m³/s.
  2. Use 3 flow channels and 11 potential drops for 1.08e-7 m²/s per unit width.
  3. The final head drop gives an exit gradient of 0.2273. Divide the critical gradient 0.9126 by that value for exit F.S. = 4.015.
Darcy flow2.45e-7 m³/sPore velocity1.59e-7 m/sExit gradient0.227Exit F.S.4.02
Original case inputs
Head difference ΔH1.8 m
Seepage length L5.5 m
Hydraulic conductivity k2.20e-7 m/s
Cross-section A3.4 m²
Flow channels Nf3
Potential drops Nd11
Final drop spacing0.72 m
Solids specific gravity Gs2.67
Exit soil void ratio e0.83
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.