Worked example

Upward exit near the boiling gradient

An upward exit through fine sand has a short last potential cell.

Darcy flow
2.44e-4 m³/s
Pore velocity
8.84e-5 m/s
Exit gradient
1.222
Exit F.S.
0.82
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 4.4 m4 channels / 8 dropsExit F.S. / 30.82
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient exceeds the target. Review local exit conditions and filters.

Calculation details
Average Darcy gradient ΔH/L0.3667
Darcy velocity3.48e-5 m/s
Porosity from exit soil void ratio39.4 %
Flow-net discharge per unit width2.09e-4 m²/s
Head loss per potential drop0.55 m
Critical upward gradient1.006
Target maximum exit gradient0.335

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The local gradient exceeds the critical gradient even though the full-path Darcy gradient is much smaller.

  1. Divide 4.4 m by 12 m for i = 0.3667. Multiply ki by the section area to get Q = 2.44e-4 m³/s.
  2. Use 4 flow channels and 8 potential drops for 2.09e-4 m²/s per unit width.
  3. The final head drop gives an exit gradient of 1.2222. Divide the critical gradient 1.0061 by that value for exit F.S. = 0.823.
Darcy flow2.44e-4 m³/sPore velocity8.84e-5 m/sExit gradient1.222Exit F.S.0.82
Original case inputs
Head difference ΔH4.4 m
Seepage length L12 m
Hydraulic conductivity k9.50e-5 m/s
Cross-section A7 m²
Flow channels Nf4
Potential drops Nd8
Final drop spacing0.45 m
Solids specific gravity Gs2.66
Exit soil void ratio e0.65
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.

More worked examples