Worked example
Upward exit near the boiling gradient
An upward exit through fine sand has a short last potential cell.
Results
Edit inputs ↓- Darcy flow
- 2.44e-4 m³/s
- Pore velocity
- 8.84e-5 m/s
- Exit gradient
- 1.222
- Exit F.S.
- 0.82
- Flow line
- Potential drop
- Exit cell
The upward exit gradient exceeds the target. Review local exit conditions and filters.
Calculation details
| Average Darcy gradient ΔH/L | 0.3667 |
|---|---|
| Darcy velocity | 3.48e-5 m/s |
| Porosity from exit soil void ratio | 39.4 % |
| Flow-net discharge per unit width | 2.09e-4 m²/s |
| Head loss per potential drop | 0.55 m |
| Critical upward gradient | 1.006 |
| Target maximum exit gradient | 0.335 |
GeotechSoilLab · Screening sheet · Metric SI
Upward exit near the boiling gradient
| Head difference ΔH | 4.4 m |
|---|---|
| Seepage length L | 12 m |
| Hydraulic conductivity k | 9.50e-5 m/s |
| Cross-section A | 7 m² |
| Flow channels Nf | 4 |
| Potential drops Nd | 8 |
| Final drop spacing | 0.45 m |
| Solids specific gravity Gs | 2.66 |
| Exit soil void ratio e | 0.65 |
| Target exit safety factor | 3 |
| Darcy flow | 2.44e-4 m³/s |
|---|---|
| Pore velocity | 8.84e-5 m/s |
| Exit gradient | 1.222 |
| Exit F.S. | 0.82 |
| Average Darcy gradient ΔH/L | 0.3667 |
| Darcy velocity | 3.48e-5 m/s |
| Porosity from exit soil void ratio | 39.4 % |
| Flow-net discharge per unit width | 2.09e-4 m²/s |
| Head loss per potential drop | 0.55 m |
| Critical upward gradient | 1.006 |
| Target maximum exit gradient | 0.335 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
The local gradient exceeds the critical gradient even though the full-path Darcy gradient is much smaller.
- Divide 4.4 m by 12 m for i = 0.3667. Multiply ki by the section area to get Q = 2.44e-4 m³/s.
- Use 4 flow channels and 8 potential drops for 2.09e-4 m²/s per unit width.
- The final head drop gives an exit gradient of 1.2222. Divide the critical gradient 1.0061 by that value for exit F.S. = 0.823.
Darcy flow2.44e-4 m³/sPore velocity8.84e-5 m/sExit gradient1.222Exit F.S.0.82
Original case inputs
| Head difference ΔH | 4.4 m |
|---|---|
| Seepage length L | 12 m |
| Hydraulic conductivity k | 9.50e-5 m/s |
| Cross-section A | 7 m² |
| Flow channels Nf | 4 |
| Potential drops Nd | 8 |
| Final drop spacing | 0.45 m |
| Solids specific gravity Gs | 2.66 |
| Exit soil void ratio e | 0.65 |
| Target exit safety factor | 3 |
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
More worked examples
- Darcy flow through a sand columnA bench permeameter measures steady flow through a small sand cross-section.
- Flow net below a sheet pile cutoffAn illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
- Low-conductivity silt seepageA silty layer transmits a small steady discharge under a sustained head difference.
- Equal head across a seepage sectionWater levels are equal across the section in a steady-state snapshot.
- Exit cell spacing and piping marginA filter study examines a relatively long spacing between the last equipotentials at the toe.