Seepage & exit gradient
Compute Darcy discharge, pore velocity, flow-net discharge and the upward exit-gradient screen.
Results
Edit inputs ↓- Darcy flow
- 1.05e-4 m³/s
- Pore velocity
- 6.73e-5 m/s
- Exit gradient
- 0.292
- Exit F.S.
- 3.49
- Flow line
- Potential drop
- Exit cell
The upward exit gradient meets the entered safety-factor target.
Calculation details
| Average Darcy gradient ΔH/L | 0.35 |
|---|---|
| Darcy velocity | 2.62e-5 m/s |
| Porosity from exit soil void ratio | 39 % |
| Flow-net discharge per unit width | 7.00e-5 m²/s |
| Head loss per potential drop | 0.233 m |
| Critical upward gradient | 1.018 |
| Target maximum exit gradient | 0.339 |
GeotechSoilLab · Screening sheet · Metric SI
Seepage & exit gradient
| Head difference ΔH | 2.8 m |
|---|---|
| Seepage length L | 8 m |
| Hydraulic conductivity k | 7.50e-5 m/s |
| Cross-section A | 4 m² |
| Flow channels Nf | 4 |
| Potential drops Nd | 12 |
| Final drop spacing | 0.8 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.64 |
| Target exit safety factor | 3 |
| Darcy flow | 1.05e-4 m³/s |
|---|---|
| Pore velocity | 6.73e-5 m/s |
| Exit gradient | 0.292 |
| Exit F.S. | 3.49 |
| Average Darcy gradient ΔH/L | 0.35 |
| Darcy velocity | 2.62e-5 m/s |
| Porosity from exit soil void ratio | 39 % |
| Flow-net discharge per unit width | 7.00e-5 m²/s |
| Head loss per potential drop | 0.233 m |
| Critical upward gradient | 1.018 |
| Target maximum exit gradient | 0.339 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
Worked examples
- Darcy flow through a sand columnA bench permeameter measures steady flow through a small sand cross-section.
- Flow net below a sheet pile cutoffAn illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
- Upward exit near the boiling gradientAn upward exit through fine sand has a short last potential cell.