Worked example
Slope saturated to the surface
Long-duration seepage brings the phreatic line to the slope surface.
Results
Edit inputs ↓- Static F.S.
- 0.89
- Seismic F.S.
- 0.89
- Dry F.S.
- 1.67
- Pore ratio
- 0.401
- Slip plane
- Phreatic line
- Driving load
At least one applicable slope factor falls below the displayed screening limit.
Calculation details
| Average soil unit weight | 21 kN/m³ |
|---|---|
| Slip-plane pore pressure u | 9.27 kPa |
| Static effective normal stress | 10.58 kPa |
| Static driving shear stress | 8.02 kPa |
| Seismic effective normal stress | 10.58 kPa |
| Seismic driving shear stress | 8.02 kPa |
| Static F.S. minus 1.50 | -0.61 |
| Seismic F.S. minus 1.10 | -0.21 |
GeotechSoilLab · Screening sheet · Metric SI
Slope saturated to the surface
| Slope angle β | 22 ° |
|---|---|
| Vertical plane depth z | 1.1 m |
| Cohesion c′ | 0 kPa |
| Friction angle φ′ | 34 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 21 kN/m³ |
| Water height ratio m | 1 |
| Seismic coefficient kh | 0 |
| Static F.S. | 0.89 |
|---|---|
| Seismic F.S. | 0.89 |
| Dry F.S. | 1.67 |
| Pore ratio | 0.401 |
| Average soil unit weight | 21 kN/m³ |
| Slip-plane pore pressure u | 9.27 kPa |
| Static effective normal stress | 10.58 kPa |
| Static driving shear stress | 8.02 kPa |
| Seismic effective normal stress | 10.58 kPa |
| Seismic driving shear stress | 8.02 kPa |
| Static F.S. minus 1.50 | -0.61 |
| Seismic F.S. minus 1.10 | -0.21 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Effective normal stress is based on buoyant weight. The dry and saturated frictional safety factors differ markedly.
- Parallel seepage gives u = 9.274 kPa. The static effective normal and driving shear stresses are 10.585 kPa and 8.023 kPa.
- Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 0.89.
- With kₕ = 0, the pseudo-static F.S. is 0.89.
Static F.S.0.89Seismic F.S.0.89Dry F.S.1.67Pore ratio0.401
Original case inputs
| Slope angle β | 22 ° |
|---|---|
| Vertical plane depth z | 1.1 m |
| Cohesion c′ | 0 kPa |
| Friction angle φ′ | 34 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 21 kN/m³ |
| Water height ratio m | 1 |
| Seismic coefficient kh | 0 |
Method & assumptions
- Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
- Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
- The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
- The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.
More worked examples
- Dry frictional soil slopeA dry granular slope has a shallow plane parallel to the ground surface.
- Slope with a halfway phreatic lineGroundwater occupies the lower half of a thin residual-soil layer over bedrock.
- Pseudo-static slope with horizontal loadingA preliminary seismic screen applies a horizontal inertia coefficient on a shallow sliding layer.
- Steep slope below the static targetA steep saturated residual-soil slope has modest cohesion and a shallow planar slip surface.
- Seismic slope with loss of normal contactA deliberately severe combination sets the phreatic line at grade and applies strong downslope acceleration.