Worked example

Slope with a halfway phreatic line

Groundwater occupies the lower half of a thin residual-soil layer over bedrock.

Static F.S.
1.39
Seismic F.S.
1.39
Dry F.S.
1.73
Pore ratio
0.201
Slope slice & parallel slip plane Schematic
Slope slice & parallel slip plane, schematic Slope 28°z 1.7 mWater ratio 0.5kₕ 0Static / 1.501.39Seismic / 1.101.39
  • Slip plane
  • Phreatic line
  • Driving load

At least one applicable slope factor falls below the displayed screening limit.

Calculation details
Average soil unit weight19 kN/m³
Slip-plane pore pressure u6.5 kPa
Static effective normal stress18.68 kPa
Static driving shear stress13.39 kPa
Seismic effective normal stress18.68 kPa
Seismic driving shear stress13.39 kPa
Static F.S. minus 1.50-0.105
Seismic F.S. minus 1.100.295

Inputs

Slope and shear strength
Water and seismic loading
0 is dry; 1 puts parallel seepage at the surface.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The weight calculation uses both moist and saturated soil. Pressure at the plane comes from the saturated depth.

  1. Parallel seepage gives u = 6.498 kPa. The static effective normal and driving shear stresses are 18.683 kPa and 13.389 kPa.
  2. Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 1.395.
  3. With kₕ = 0, the pseudo-static F.S. is 1.395.
Static F.S.1.39Seismic F.S.1.39Dry F.S.1.73Pore ratio0.201
Original case inputs
Slope angle β28 °
Vertical plane depth z1.7 m
Cohesion c′7 kPa
Friction angle φ′32 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water height ratio m0.5
Seismic coefficient kh0

Method & assumptions

  1. Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
  2. Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
  3. The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
  4. The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.