Worked example

Pseudo-static slope with horizontal loading

A preliminary seismic screen applies a horizontal inertia coefficient on a shallow sliding layer.

Static F.S.
1.78
Seismic F.S.
1.24
Dry F.S.
2.03
Pore ratio
0.13
Slope slice & parallel slip plane Schematic
Slope slice & parallel slip plane, schematic Slope 25°z 6.56 ftWater ratio 0.3kₕ 0.16Static / 1.501.78Seismic / 1.101.24
  • Slip plane
  • Phreatic line
  • Driving load

Computed factors meet the displayed slope screening limits.

Calculation details
Average soil unit weight118.41 pcf
Slip-plane pore pressure u100.94 psf
Static effective normal stress537.23 psf
Static driving shear stress297.58 psf
Seismic effective normal stress489.62 psf
Seismic driving shear stress399.69 psf
Static F.S. minus 1.500.279
Seismic F.S. minus 1.100.144

Inputs

Slope and shear strength
Water and seismic loading
0 is dry; 1 puts parallel seepage at the surface.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The horizontal force increases the driving shear and reduces effective normal stress.

  1. Parallel seepage gives u = 100.941 psf. The static effective normal and driving shear stresses are 537.231 psf and 297.585 psf.
  2. Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 1.779.
  3. With kₕ = 0.16, the pseudo-static F.S. is 1.244.
Static F.S.1.78Seismic F.S.1.24Dry F.S.2.03Pore ratio0.13
Original case inputs
Slope angle β25 °
Vertical plane depth z6.56168 ft
Cohesion c′167.08347 psf
Friction angle φ′34 °
Moist weight γ114.58585 pcf
Saturated weight γsat127.31761 pcf
Water height ratio m0.3
Seismic coefficient kh0.16

Method & assumptions

  1. Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
  2. Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
  3. The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
  4. The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.