Worked example

Steep slope below the static target

A steep saturated residual-soil slope has modest cohesion and a shallow planar slip surface.

Static F.S.
0.73
Seismic F.S.
0.61
Dry F.S.
0.91
Pore ratio
0.15
Slope slice & parallel slip plane Schematic
Slope slice & parallel slip plane, schematic Slope 35°z 2 mWater ratio 0.43kₕ 0.08Static / 1.500.73Seismic / 1.100.61
  • Slip plane
  • Phreatic line
  • Driving load

At least one applicable slope factor falls below the displayed screening limit.

Calculation details
Average soil unit weight18.86 kN/m³
Slip-plane pore pressure u5.66 kPa
Static effective normal stress19.65 kPa
Static driving shear stress17.72 kPa
Seismic effective normal stress18.23 kPa
Seismic driving shear stress19.75 kPa
Static F.S. minus 1.50-0.773
Seismic F.S. minus 1.10-0.487

Inputs

Slope and shear strength
Water and seismic loading
0 is dry; 1 puts parallel seepage at the surface.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The computed static reserve is negative relative to the displayed 1.50 screening threshold.

  1. Parallel seepage gives u = 5.659 kPa. The static effective normal and driving shear stresses are 19.651 kPa and 17.723 kPa.
  2. Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 0.727.
  3. With kₕ = 0.08, the pseudo-static F.S. is 0.613.
Static F.S.0.73Seismic F.S.0.61Dry F.S.0.91Pore ratio0.15
Original case inputs
Slope angle β35 °
Vertical plane depth z2 m
Cohesion c′2 kPa
Friction angle φ′29 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water height ratio m0.43
Seismic coefficient kh0.08

Method & assumptions

  1. Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
  2. Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
  3. The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
  4. The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.