Retaining wall stability
Resolve Rankine or Coulomb active thrust and check sliding, overturning and base contact.
Results
Edit inputs ↓- Active thrust
- 43.3 kN/m
- Sliding F.S.
- 1.61
- Overturn F.S.
- 3.02
- Eccentricity
- 0.234 m
- Active pressure
- Surcharge
- Resultant
Sliding, overturning and middle-third screens all meet the displayed limits.
Calculation details
| Active coefficient Ka | 0.307 |
|---|---|
| Reference passive Kp (smooth, level toe) | 3.255 |
| Effective retained height at heel | 3.4 m |
| Total horizontal driving force | 43.3 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1.27 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.5 m |
| Middle-third eccentricity limit B/6 | 0.417 m |
| Base resultant from toe | 1.016 m |
| Toe bearing pressure | 87.4 kPa |
| Heel bearing pressure | 24.5 kPa |
| Maximum contact pressure | 87.4 kPa |
| Minimum contact pressure | 24.5 kPa |
| Compression contact width | 2.5 m |
| Concrete stem weight | 24.48 kN/m |
| Concrete base weight | 21 kN/m |
| Soil weight over heel | 94.35 kN/m |
| Net downward load | 139.83 kN/m |
| Resisting moment about toe | 212.17 kN·m/m |
| Driving moment about toe | 70.15 kN·m/m |
GeotechSoilLab · Screening sheet · Metric SI
Retaining wall stability
| Stem height H | 3.4 m |
|---|---|
| Stem thickness | 0.3 m |
| Toe projection | 0.7 m |
| Heel projection | 1.5 m |
| Base thickness | 0.35 m |
| Concrete weight | 24 kN/m³ |
| Pressure method | Rankine |
| Friction angle φ′ | 32 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 18.5 kN/m³ |
| Uniform surcharge q | 10 kPa |
| Base friction μ | 0.5 |
| Backfill water | Drained |
| Active thrust | 43.3 kN/m |
|---|---|
| Sliding F.S. | 1.61 |
| Overturn F.S. | 3.02 |
| Eccentricity | 0.234 m |
| Active coefficient Ka | 0.307 |
| Reference passive Kp (smooth, level toe) | 3.255 |
| Effective retained height at heel | 3.4 m |
| Total horizontal driving force | 43.3 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1.27 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.5 m |
| Middle-third eccentricity limit B/6 | 0.417 m |
| Base resultant from toe | 1.016 m |
| Toe bearing pressure | 87.4 kPa |
| Heel bearing pressure | 24.5 kPa |
| Maximum contact pressure | 87.4 kPa |
| Minimum contact pressure | 24.5 kPa |
| Compression contact width | 2.5 m |
| Concrete stem weight | 24.48 kN/m |
| Concrete base weight | 21 kN/m |
| Soil weight over heel | 94.35 kN/m |
| Net downward load | 139.83 kN/m |
| Resisting moment about toe | 212.17 kN·m/m |
| Driving moment about toe | 70.15 kN·m/m |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Method & assumptions
- Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
- For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
- The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
- Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
- Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.
Worked examples
- Rankine wall with level backfillA short cantilever wall supports a level landscape fill without a surface surcharge.
- Retaining wall with traffic surchargeAn adjacent traffic area is approximated by a uniform 22 kPa surcharge.
- Rankine wall with a sloping backfillA landscaped backfill rises away from the retaining stem at 15°.
- Coulomb wall with interface frictionA preliminary gravity-block check uses a Coulomb interface angle of 16° and slightly rising backfill.
- Retaining wall with partial base contactA narrow base under surcharge is used to illustrate the transition from full to partial soil contact.