Worked example

Rankine wall with a sloping backfill

A landscaped backfill rises away from the retaining stem at 15°.

Active thrust
44.01 kN/m
Sliding F.S.
1.76
Overturn F.S.
3.45
Eccentricity
0.108 m
Wall section & lateral pressure Schematic
Wall section & lateral pressure, schematic Backfill 15°Lateral pressureBase 2.5 mPₐ 44.01 kN/mGoverning limit ratio117.5%
  • Active pressure
  • Surcharge
  • Resultant

Sliding, overturning and middle-third screens all meet the displayed limits.

Calculation details
Active coefficient Ka0.311
Reference passive Kp (smooth, level toe)3.537
Effective retained height at heel3.6 m
Total horizontal driving force42.51 kN/m
Downward active force11.39 kN/m
Thrust height above base top1.29 m
Horizontal water thrust0 kN/m
Base uplift0 kN/m
Base width B2.5 m
Middle-third eccentricity limit B/60.417 m
Base resultant from toe1.142 m
Toe bearing pressure75.5 kPa
Heel bearing pressure44.4 kPa
Maximum contact pressure75.5 kPa
Minimum contact pressure44.4 kPa
Compression contact width2.5 m
Concrete stem weight23.04 kN/m
Concrete base weight21 kN/m
Soil weight over heel94.38 kN/m
Net downward load149.81 kN/m
Resisting moment about toe240.86 kN·m/m
Driving moment about toe69.81 kN·m/m

Inputs

Wall section
Backfill and interface
Groundwater behind wall

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The effective pressure plane at the heel is taller than the stem. The active force inclines downward with the backfill slope.

  1. Use Kₐ = 0.3108 over a retained height of 3.602 m. The active thrust is 44.01 kN/m at 1.292 m above the base top.
  2. Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 1.762. Dividing 240.864 kN·m/m by 69.812 kN·m/m gives an overturning F.S. of 3.45.
  3. Compare the absolute eccentricity of 0.108 m with B/6 = 0.417 m.
Active thrust44.01 kN/mSliding F.S.1.76Overturn F.S.3.45Eccentricity0.108 m
Original case inputs
Stem height H3.2 m
Stem thickness0.3 m
Toe projection0.7 m
Heel projection1.5 m
Base thickness0.35 m
Concrete weight24 kN/m³
Pressure methodRankine
Friction angle φ′34 °
Backfill slope β15 °
Backfill weight γ18.5 kN/m³
Uniform surcharge q6 kPa
Base friction μ0.5
Backfill waterDrained

Method & assumptions

  1. Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
  2. For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
  3. The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
  4. Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
  5. Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.