Worked example

Retaining wall with partial base contact

A narrow base under surcharge is used to illustrate the transition from full to partial soil contact.

Active thrust
58.96 kN/m
Sliding F.S.
1.05
Overturn F.S.
1.71
Eccentricity
0.567 m
Wall section & lateral pressure Schematic
Wall section & lateral pressure, schematic Backfill 0°Lateral pressureBase 2.21 mPₐ 58.96 kN/mGoverning limit ratio64.9%
  • Active pressure
  • Surcharge
  • Resultant

One or more stability screens fall below the displayed limits. The resultant is outside the middle third. Bearing uses a compression-only contact triangle.

Calculation details
Active coefficient Ka0.307
Reference passive Kp (smooth, level toe)3.255
Effective retained height at heel3.6 m
Total horizontal driving force58.96 kN/m
Downward active force0 kN/m
Thrust height above base top1.43 m
Horizontal water thrust0 kN/m
Base uplift0 kN/m
Base width B2.21 m
Middle-third eccentricity limit B/60.368 m
Base resultant from toe0.538 m
Toe bearing pressure170.9 kPa
Heel bearing pressure0 kPa
Maximum contact pressure170.9 kPa
Minimum contact pressure0 kPa
Compression contact width1.613 m
Concrete stem weight29.38 kN/m
Concrete base weight18.56 kN/m
Soil weight over heel89.91 kN/m
Net downward load137.85 kN/m
Resisting moment about toe178.79 kN·m/m
Driving moment about toe104.66 kN·m/m

Inputs

Wall section
Backfill and interface
Groundwater behind wall

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

When the resultant remains inside the foundation but leaves the middle third, the bearing pressure is triangular over a reduced width.

  1. Use Kₐ = 0.3073 over a retained height of 3.6 m. The active thrust is 58.957 kN/m at 1.425 m above the base top.
  2. Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 1.052. Dividing 178.795 kN·m/m by 104.657 kN·m/m gives an overturning F.S. of 1.708.
  3. Compare the absolute eccentricity of 0.567 m with B/6 = 0.368 m.
Active thrust58.96 kN/mSliding F.S.1.05Overturn F.S.1.71Eccentricity0.567 m
Original case inputs
Stem height H3.6 m
Stem thickness0.34 m
Toe projection0.52 m
Heel projection1.35 m
Base thickness0.35 m
Concrete weight24 kN/m³
Pressure methodRankine
Friction angle φ′32 °
Backfill slope β0 °
Backfill weight γ18.5 kN/m³
Uniform surcharge q20 kPa
Base friction μ0.45
Backfill waterDrained

Method & assumptions

  1. Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
  2. For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
  3. The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
  4. Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
  5. Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.