Worked example
Retaining wall with partial base contact
A narrow base under surcharge is used to illustrate the transition from full to partial soil contact.
Results
Edit inputs ↓- Active thrust
- 58.96 kN/m
- Sliding F.S.
- 1.05
- Overturn F.S.
- 1.71
- Eccentricity
- 0.567 m
- Active pressure
- Surcharge
- Resultant
One or more stability screens fall below the displayed limits. The resultant is outside the middle third. Bearing uses a compression-only contact triangle.
Calculation details
| Active coefficient Ka | 0.307 |
|---|---|
| Reference passive Kp (smooth, level toe) | 3.255 |
| Effective retained height at heel | 3.6 m |
| Total horizontal driving force | 58.96 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1.43 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.21 m |
| Middle-third eccentricity limit B/6 | 0.368 m |
| Base resultant from toe | 0.538 m |
| Toe bearing pressure | 170.9 kPa |
| Heel bearing pressure | 0 kPa |
| Maximum contact pressure | 170.9 kPa |
| Minimum contact pressure | 0 kPa |
| Compression contact width | 1.613 m |
| Concrete stem weight | 29.38 kN/m |
| Concrete base weight | 18.56 kN/m |
| Soil weight over heel | 89.91 kN/m |
| Net downward load | 137.85 kN/m |
| Resisting moment about toe | 178.79 kN·m/m |
| Driving moment about toe | 104.66 kN·m/m |
GeotechSoilLab · Screening sheet · Metric SI
Retaining wall with partial base contact
| Stem height H | 3.6 m |
|---|---|
| Stem thickness | 0.34 m |
| Toe projection | 0.52 m |
| Heel projection | 1.35 m |
| Base thickness | 0.35 m |
| Concrete weight | 24 kN/m³ |
| Pressure method | Rankine |
| Friction angle φ′ | 32 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 18.5 kN/m³ |
| Uniform surcharge q | 20 kPa |
| Base friction μ | 0.45 |
| Backfill water | Drained |
| Active thrust | 58.96 kN/m |
|---|---|
| Sliding F.S. | 1.05 |
| Overturn F.S. | 1.71 |
| Eccentricity | 0.567 m |
| Active coefficient Ka | 0.307 |
| Reference passive Kp (smooth, level toe) | 3.255 |
| Effective retained height at heel | 3.6 m |
| Total horizontal driving force | 58.96 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1.43 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.21 m |
| Middle-third eccentricity limit B/6 | 0.368 m |
| Base resultant from toe | 0.538 m |
| Toe bearing pressure | 170.9 kPa |
| Heel bearing pressure | 0 kPa |
| Maximum contact pressure | 170.9 kPa |
| Minimum contact pressure | 0 kPa |
| Compression contact width | 1.613 m |
| Concrete stem weight | 29.38 kN/m |
| Concrete base weight | 18.56 kN/m |
| Soil weight over heel | 89.91 kN/m |
| Net downward load | 137.85 kN/m |
| Resisting moment about toe | 178.79 kN·m/m |
| Driving moment about toe | 104.66 kN·m/m |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
When the resultant remains inside the foundation but leaves the middle third, the bearing pressure is triangular over a reduced width.
- Use Kₐ = 0.3073 over a retained height of 3.6 m. The active thrust is 58.957 kN/m at 1.425 m above the base top.
- Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 1.052. Dividing 178.795 kN·m/m by 104.657 kN·m/m gives an overturning F.S. of 1.708.
- Compare the absolute eccentricity of 0.567 m with B/6 = 0.368 m.
Original case inputs
| Stem height H | 3.6 m |
|---|---|
| Stem thickness | 0.34 m |
| Toe projection | 0.52 m |
| Heel projection | 1.35 m |
| Base thickness | 0.35 m |
| Concrete weight | 24 kN/m³ |
| Pressure method | Rankine |
| Friction angle φ′ | 32 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 18.5 kN/m³ |
| Uniform surcharge q | 20 kPa |
| Base friction μ | 0.45 |
| Backfill water | Drained |
Method & assumptions
- Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
- For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
- The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
- Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
- Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.
More worked examples
- Rankine wall with level backfillA short cantilever wall supports a level landscape fill without a surface surcharge.
- Retaining wall with traffic surchargeAn adjacent traffic area is approximated by a uniform 22 kPa surcharge.
- Rankine wall with a sloping backfillA landscaped backfill rises away from the retaining stem at 15°.
- Coulomb wall with interface frictionA preliminary gravity-block check uses a Coulomb interface angle of 16° and slightly rising backfill.
- Retaining wall with resultant beyond the toeAn intentionally undersized section demonstrates a failed equilibrium screen.