Worked example

Clayey sand (SC)

The coarse portion is mainly sand and the fines plot above the A-line.

USCS group
SC
Plasticity PI
18 %
Liquidity LI
0.39
Uniformity Cu
—
Casagrande plasticity chart Schematic
Casagrande plasticity chart, schematic Plasticity index (%)Fines CL65050100Sample SCLiquid limit (%)U-line screenWithin envelope
  • A-line
  • U-line
  • Specimen

The measured limits plot within the U-line screening envelope.

Calculation details
Dominant fractionSand-dominant
Fines groupCL
Gradation—
Curvature coefficient Cc—
A-line ordinate at LL12.4 %
U-line ordinate at LL26.1 %
Gravel retained on No. 48 %
Sand between No. 4 and No. 20069 %

Inputs

Grain-size distribution
Atterberg limits

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

With more than 12% clayey fines, the group symbol is SC even without D-size data.

  1. 23% passes No. 200. The dominant fraction is sand-dominant.
  2. Subtract PL = 19% from LL = 37% for PI = 18%. The A-line at this LL is 12.41%.
  3. The gradation and fines branch gives SC.
USCS groupSCPlasticity PI18 %Liquidity LI0.39Uniformity Cu—
Original case inputs
Passing No. 492 %
Passing No. 20023 %
Particle diameter D₁₀—
Particle diameter D₃₀—
Particle diameter D₆₀—
Fines testMeasured limits
Liquid limit LL37 %
Plastic limit PL19 %
Natural water content26 %

Method & assumptions

  1. Use the portion passing 75 mm. At 50% or more passing No. 200 the soil is fine-grained. In coarse soil, gravel must exceed half the coarse fraction to control the symbol.
  2. With less than 5% fines, grade using Cu = D₆₀/D₁₀ and Cc = D₃₀²/(D₁₀D₆₀). Well-graded gravel requires Cu ≥ 4 and sand Cu ≥ 6. Both require 1 ≤ Cc ≤ 3. From 5% to 12% fines, assign a dual symbol. Enter percentile diameters from the same gradation curve as the passing percentages.
  3. PI = LL − PL and LI = (w − PL)/PI. The A-line is PI = 0.73(LL − 20). The low-LL CL-ML region is on or above the A-line with PI from 4 to 7. LL = 50 separates low and high liquid limits.
  4. The U-line uses PI = 0.9(LL − 8) and an LL = 16 lower segment. Points above or left of that envelope flag a test-data check. Use lab evidence to distinguish organic material and peat.

More worked examples