Worked example
Clayey sand (SC)
The coarse portion is mainly sand and the fines plot above the A-line.
Results
Edit inputs ↓- USCS group
- SC
- Plasticity PI
- 18 %
- Liquidity LI
- 0.39
- Uniformity Cu
- —
- A-line
- U-line
- Specimen
The measured limits plot within the U-line screening envelope.
Calculation details
| Dominant fraction | Sand-dominant |
|---|---|
| Fines group | CL |
| Gradation | — |
| Curvature coefficient Cc | — |
| A-line ordinate at LL | 12.4 % |
| U-line ordinate at LL | 26.1 % |
| Gravel retained on No. 4 | 8 % |
| Sand between No. 4 and No. 200 | 69 % |
GeotechSoilLab · Screening sheet · US customary
Clayey sand (SC)
| Passing No. 4 | 92 % |
|---|---|
| Passing No. 200 | 23 % |
| Particle diameter D₁₀ | — |
| Particle diameter D₃₀ | — |
| Particle diameter D₆₀ | — |
| Fines test | Measured limits |
| Liquid limit LL | 37 % |
| Plastic limit PL | 19 % |
| Natural water content | 26 % |
| USCS group | SC |
|---|---|
| Plasticity PI | 18 % |
| Liquidity LI | 0.39 |
| Uniformity Cu | — |
| Dominant fraction | Sand-dominant |
| Fines group | CL |
| Gradation | — |
| Curvature coefficient Cc | — |
| A-line ordinate at LL | 12.4 % |
| U-line ordinate at LL | 26.1 % |
| Gravel retained on No. 4 | 8 % |
| Sand between No. 4 and No. 200 | 69 % |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
With more than 12% clayey fines, the group symbol is SC even without D-size data.
- 23% passes No. 200. The dominant fraction is sand-dominant.
- Subtract PL = 19% from LL = 37% for PI = 18%. The A-line at this LL is 12.41%.
- The gradation and fines branch gives SC.
USCS groupSCPlasticity PI18 %Liquidity LI0.39Uniformity Cu—
Original case inputs
| Passing No. 4 | 92 % |
|---|---|
| Passing No. 200 | 23 % |
| Particle diameter D₁₀ | — |
| Particle diameter D₃₀ | — |
| Particle diameter D₆₀ | — |
| Fines test | Measured limits |
| Liquid limit LL | 37 % |
| Plastic limit PL | 19 % |
| Natural water content | 26 % |
Method & assumptions
- Use the portion passing 75 mm. At 50% or more passing No. 200 the soil is fine-grained. In coarse soil, gravel must exceed half the coarse fraction to control the symbol.
- With less than 5% fines, grade using Cu = D₆₀/D₁₀ and Cc = D₃₀²/(D₁₀D₆₀). Well-graded gravel requires Cu ≥ 4 and sand Cu ≥ 6. Both require 1 ≤ Cc ≤ 3. From 5% to 12% fines, assign a dual symbol. Enter percentile diameters from the same gradation curve as the passing percentages.
- PI = LL − PL and LI = (w − PL)/PI. The A-line is PI = 0.73(LL − 20). The low-LL CL-ML region is on or above the A-line with PI from 4 to 7. LL = 50 separates low and high liquid limits.
- The U-line uses PI = 0.9(LL − 8) and an LL = 16 lower segment. Points above or left of that envelope flag a test-data check. Use lab evidence to distinguish organic material and peat.
More worked examples
- Well-graded clean sand (SW)Sieve results describe a clean sand with a broad particle-size range.
- Gravel with a dual symbol (GP-GM)A gravel-dominant specimen contains 8% low-plasticity silty fines.
- High-plasticity clay (CH)A fine-grained inorganic specimen has a high liquid limit and a large plasticity index.
- Low-plasticity silty clay (CL-ML)A fines-dominated soil plots in the low-plasticity overlap band.