Worked example

High-plasticity clay (CH)

A fine-grained inorganic specimen has a high liquid limit and a large plasticity index.

USCS group
CH
Plasticity PI
44 %
Liquidity LI
0.34
Uniformity Cu
—
Casagrande plasticity chart Schematic
Casagrande plasticity chart, schematic Plasticity index (%)Fines CH65050100Sample CHLiquid limit (%)U-line screenWithin envelope
  • A-line
  • U-line
  • Specimen

The measured limits plot within the U-line screening envelope.

Calculation details
Dominant fractionFine-grained soil
Fines groupCH
Gradation—
Curvature coefficient Cc—
A-line ordinate at LL40.9 %
U-line ordinate at LL61.2 %
Gravel retained on No. 42 %
Sand between No. 4 and No. 2009 %

Inputs

Grain-size distribution
Atterberg limits

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The specimen plots above the A-line on the LL ≥ 50 side. Liquidity index uses its natural water content.

  1. 89% passes No. 200. The dominant fraction is fine-grained soil.
  2. Subtract PL = 32% from LL = 76% for PI = 44%. The A-line at this LL is 40.88%.
  3. The gradation and fines branch gives CH.
USCS groupCHPlasticity PI44 %Liquidity LI0.34Uniformity Cu—
Original case inputs
Passing No. 498 %
Passing No. 20089 %
Particle diameter D₁₀—
Particle diameter D₃₀—
Particle diameter D₆₀—
Fines testMeasured limits
Liquid limit LL76 %
Plastic limit PL32 %
Natural water content47 %

Method & assumptions

  1. Use the portion passing 75 mm. At 50% or more passing No. 200 the soil is fine-grained. In coarse soil, gravel must exceed half the coarse fraction to control the symbol.
  2. With less than 5% fines, grade using Cu = D₆₀/D₁₀ and Cc = D₃₀²/(D₁₀D₆₀). Well-graded gravel requires Cu ≥ 4 and sand Cu ≥ 6. Both require 1 ≤ Cc ≤ 3. From 5% to 12% fines, assign a dual symbol. Enter percentile diameters from the same gradation curve as the passing percentages.
  3. PI = LL − PL and LI = (w − PL)/PI. The A-line is PI = 0.73(LL − 20). The low-LL CL-ML region is on or above the A-line with PI from 4 to 7. LL = 50 separates low and high liquid limits.
  4. The U-line uses PI = 0.9(LL − 8) and an LL = 16 lower segment. Points above or left of that envelope flag a test-data check. Use lab evidence to distinguish organic material and peat.

More worked examples