PVB laminate under a cold gust

Two equal glass plies use a short-duration cold-condition interlayer modulus.

Wölfel–Bennison · EN 16612 context

Inputs

Glass and support
mm
mm
mm
m
Interlayer shear modulus

Ionoplast includes products such as SentryGlas®.

Screening result

Interlayer shear measurably increases the modeled bending stiffness.

Pass
Shear transfer
96.5%
Defl. eff. t
13.38mm
Ply 1 stress t
13.45mm
Ply 2 stress t
13.45mm
Laminated glass section and shear couplingLaminated glass stiffness. Shear transfer 96.5 %. Defl. eff. t 13.38 mm. Ply 1 stress t 13.45 mm. Ply 2 stress t 13.45 mm.Two glass plies and interlayerSpan 1.45 mPly 1 · interlayer · ply 2Equivalent thicknessDeflection comparison at the same spanUncoupledEffectiveFull shearEffective t 13.38 mmInterlayer shear transferUncoupled50%Fully coupled

Calculation details

Applied interlayer shear modulus
40 MPa
Uncoupled effective thickness
7.56 mm
Fully coupled effective thickness
13.514 mm
Stiffness over uncoupled plies
5.547
Fraction of fully coupled stiffness
97.1 %

Formula trace in SI

  1. Interlayer coupling

    ω = G / (G + 9.6 E A* hv / L²)

    G = 40 MPa, reduced area per width A* = 3 mm, ω = 96.48 %.

  2. Equivalent bending thickness

    heff,w³ = h₁³ + h₂³ + 12ωA*H²

    Ply centroid distance H = 7.52 mm, heff,w = 13.382 mm.

  3. Surface bending stress thickness

    heff,σ,i = √[heff,w³/(hi + 2ωdi)]

    Ply 1 13.445 mm, ply 2 13.445 mm.

  4. Stiffness gain

    Ieff / Ilayered = heff,w³ / (h₁³ + h₂³)

    5.547× the uncoupled limit.