Worked example · Pickup Resonant Peak
A P-90-style pickup with the tone rolled down
A high-inductance single coil feeds a long cable and a mostly rolled-down tone control. The tone branch can dominate the response.
Try this Set the tone position to 10 and compare it with the result at 1.5. Use the same capacitor and cable for both.
Inputs
Results
Back to inputs ↑- Loaded peak
- —
- Rise above baseline
- —
- Bandwidth Q
- —
Frequency response at the output jack
- This circuit has no local peak above its low-frequency gain over the shown sweep.
| LC reference (Hz) | Low-frequency gain (dB) | Peak gain (dB) | Lower −3 dB (Hz) | Upper −3 dB (Hz) |
|---|---|---|---|---|
| 2,322.25 | -0.22 | — | — | — |
Input settings
- Pickup inductance 6.1 H
- Pickup DC resistance 8.7 kΩ
- Winding capacitance 150 pF
- Cable capacitance 620 pF
- Volume pot 500 kΩ
- Volume electrical position 10
- Tone branch Connected
- Tone pot 250 kΩ
- Tone electrical position 1.5
- Tone capacitor 47 nF
- Treble-bleed network Off
- Bleed capacitor 1,000 pF
- Bleed resistor 150 kΩ
- Following input resistance 1,000 kΩ
How the calculation works
Model each node
Pickup R and L model the source in series. Winding capacitance and the tone branch load the pickup node. Cable capacitance and input resistance load the volume wiper. The bleed network spans the upper volume leg.
Compare ideal and loaded frequencies
The LC reference uses winding plus cable capacitance at full volume. The loaded peak comes from the complete AC transfer function. Peak dB is measured above the low-frequency gain.
Interpret bandwidth Q
Q is peak frequency divided by the distance between the two half-power frequencies. Both crossings must fall within the sweep. Pot positions use linear electrical travel, so an audio-taper knob may reach the same setting at a different number.
References
Questions at the bench
Why might the P-90 example lose a visible peak when the tone is low?
Reducing the series resistance makes the tone capacitor a stronger shunt. This can damp the resonant rise into a broad roll-off.
What unit should I use for a 0.047 µF tone cap on this P-90?
Enter 47 nF. Keep cable and winding capacitances in picofarads as labeled in their own fields.