Worked example · Pickup Resonant Peak

A 2.3 H single coil with a short cable

A 250 kΩ guitar volume pot feeds a short cable. The tone branch is disconnected so the cable’s contribution is easy to see.

Try this Increase cable capacitance from 200 to 600 pF and compare the two peak positions.

Inputs

View results ↓
H0.1–30 H
kΩ0.1–80 kΩ
pF5–2,000 pF
pF0–5,000 pF
Linear wiper position from 0 to 10. 0–10
0–10
nF1–150 nF
pF10–10,000 pF
kΩ1–5,000 kΩ
kΩ10–10,000 kΩ
Loaded peak
5,842.2 Hz
Rise above baseline
6.25 dB
Bandwidth Q
1.72

Frequency response at the output jack

Frequency response at the output jackFrequency uses a logarithmic axis. The reference line shows low-frequency gain and a marker appears at a resolved peak. -36-26-15-56201001k10k20kdBFrequency (Hz)5,842 Hz
Frequency uses a logarithmic axis. The reference line shows low-frequency gain and a marker appears at a resolved peak.

Circuit checkpoints
LC reference (Hz)Low-frequency gain (dB)Peak gain (dB)Lower −3 dB (Hz)Upper −3 dB (Hz)
6,162.5-0.2563,8867,291.2
Loaded peak 5842.2 Hz

How the calculation works

Model each node

Pickup R and L model the source in series. Winding capacitance and the tone branch load the pickup node. Cable capacitance and input resistance load the volume wiper. The bleed network spans the upper volume leg.

Compare ideal and loaded frequencies

The LC reference uses winding plus cable capacitance at full volume. The loaded peak comes from the complete AC transfer function. Peak dB is measured above the low-frequency gain.

Interpret bandwidth Q

Q is peak frequency divided by the distance between the two half-power frequencies. Both crossings must fall within the sweep. Pot positions use linear electrical travel, so an audio-taper knob may reach the same setting at a different number.

References

Questions at the bench

Why does adding cable capacitance lower the peak on this single coil?

The 2.3 H inductance resonates with a larger shunt capacitance. Their ideal resonant frequency falls with the square root of capacitance.

Is cable length enough to predict this single-coil peak?

Use the cable’s measured capacitance or its capacitance per length times the length. Different cables can have different capacitance at the same length.