Worked example · Pickup Resonant Peak
A 2.3 H single coil with a short cable
A 250 kΩ guitar volume pot feeds a short cable. The tone branch is disconnected so the cable’s contribution is easy to see.
Try this Increase cable capacitance from 200 to 600 pF and compare the two peak positions.
Inputs
Results
Back to inputs ↑- Loaded peak
- 5,842.2 Hz
- Rise above baseline
- 6.25 dB
- Bandwidth Q
- 1.72
Frequency response at the output jack
| LC reference (Hz) | Low-frequency gain (dB) | Peak gain (dB) | Lower −3 dB (Hz) | Upper −3 dB (Hz) |
|---|---|---|---|---|
| 6,162.5 | -0.25 | 6 | 3,886 | 7,291.2 |
Input settings
- Pickup inductance 2.3 H
- Pickup DC resistance 5.8 kΩ
- Winding capacitance 90 pF
- Cable capacitance 200 pF
- Volume pot 250 kΩ
- Volume electrical position 10
- Tone branch Disconnected
- Tone pot 250 kΩ
- Tone electrical position 10
- Tone capacitor 22 nF
- Treble-bleed network Off
- Bleed capacitor 1,000 pF
- Bleed resistor 150 kΩ
- Following input resistance 1,000 kΩ
How the calculation works
Model each node
Pickup R and L model the source in series. Winding capacitance and the tone branch load the pickup node. Cable capacitance and input resistance load the volume wiper. The bleed network spans the upper volume leg.
Compare ideal and loaded frequencies
The LC reference uses winding plus cable capacitance at full volume. The loaded peak comes from the complete AC transfer function. Peak dB is measured above the low-frequency gain.
Interpret bandwidth Q
Q is peak frequency divided by the distance between the two half-power frequencies. Both crossings must fall within the sweep. Pot positions use linear electrical travel, so an audio-taper knob may reach the same setting at a different number.
References
Questions at the bench
Why does adding cable capacitance lower the peak on this single coil?
The 2.3 H inductance resonates with a larger shunt capacitance. Their ideal resonant frequency falls with the square root of capacitance.
Is cable length enough to predict this single-coil peak?
Use the cable’s measured capacitance or its capacitance per length times the length. Different cables can have different capacitance at the same length.