Worked example · Pickup Resonant Peak

A rolled-back bridge pickup with a parallel treble bleed

A bright bridge single coil is played with the volume wiper halfway through its electrical travel. A 1200 pF capacitor and 150 kΩ resistor span the upper leg.

Try this Set the bleed to Off, then Capacitor only. Watch the changes in both baseline level and peak shape.

Inputs

View results ↓
H0.1–30 H
kΩ0.1–80 kΩ
pF5–2,000 pF
pF0–5,000 pF
Linear wiper position from 0 to 10. 0–10
0–10
nF1–150 nF
pF10–10,000 pF
kΩ1–5,000 kΩ
kΩ10–10,000 kΩ
Loaded peak
3,583.7 Hz
Rise above baseline
2.86 dB
Bandwidth Q
0.7

Frequency response at the output jack

Frequency response at the output jackFrequency uses a logarithmic axis. The reference line shows low-frequency gain and a marker appears at a resolved peak. -36-26-15-56201001k10k20kdBFrequency (Hz)3,584 Hz
Frequency uses a logarithmic axis. The reference line shows low-frequency gain and a marker appears at a resolved peak.

Circuit checkpoints
LC reference (Hz)Low-frequency gain (dB)Peak gain (dB)Lower −3 dB (Hz)Upper −3 dB (Hz)
3,908.07-4.49-1.64315.85,412.2
Loaded peak 3583.7 Hz

How the calculation works

Model each node

Pickup R and L model the source in series. Winding capacitance and the tone branch load the pickup node. Cable capacitance and input resistance load the volume wiper. The bleed network spans the upper volume leg.

Compare ideal and loaded frequencies

The LC reference uses winding plus cable capacitance at full volume. The loaded peak comes from the complete AC transfer function. Peak dB is measured above the low-frequency gain.

Interpret bandwidth Q

Q is peak frequency divided by the distance between the two half-power frequencies. Both crossings must fall within the sweep. Pot positions use linear electrical travel, so an audio-taper knob may reach the same setting at a different number.

References

Questions at the bench

Why can the parallel bleed resistor change low-frequency level at half volume?

It shunts some of the upper pot resistance even when the cap is effectively open. That changes the wiper’s voltage divider.

When is the 1200 pF bleed most visible in this bridge pickup example?

Compare curves with the wiper below full volume. At full volume the bleed is shorted by the upper leg.