Worked example

2-inch fixture clamp cycle

A short travel and limited flow give a quick cycle. Use the standard extend and retract speeds to estimate how much time remains for dwell.

Inputs

in
in
in
psi
GPM
psi
Regeneration joins rod-side flow to pump flow at the cap port.

Anatomy

Double-acting cylinder cutaway
Double-acting cylinder cutawayPUSH FORCE4712lbfPULL FORCE2872lbfEXTEND SPEED3.676in/sCYCLE TIME2.189sPumpCap chamberRod chamberPressureReturnTank / suctionTrapped rod pressure / rating82.05%0%100% reference150%

Results

US customary
Standard push force4,712.389lbf
Pull force2,871.612lbf
Regenerative push force1,840.777lbf
Standard extend speed3.676in/s93.383mm/s
Regenerative extend speed9.412in/s239.059mm/s
Retract speed6.033in/s153.243mm/s
Selected extend + retract2.189s
Standard cycle time2.189s
Regenerative cycle time1.36s
Ideal trapped rod pressure2,461.538psi
Cap area3.142in²
Rod-side annulus area1.914in²
Cap-to-annulus area ratio1.641:1
2:1 area checkOutside 2.5% of 2:1

Worked calculation

  1. Piston areas

    A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.

  2. Force and speed

    Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.

  3. Cycle time and equal speeds

    Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.

  4. Trapped pressure

    P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.

Results for the original example inputs
Cap area3.142in²
Rod-side annulus area1.914in²
Standard push force4,712.389lbf
Regenerative push force1,840.777lbf
Selected extend + retract2.189s
Ideal trapped rod pressure2,461.538psi

Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.