Worked example

6-inch press with blocked rod port

A 4-inch rod leaves a smaller pressure area on the return side. Compare the ideal trapped pressure with the 5,000 psi rod-side rating.

Inputs

in
in
in
psi
GPM
psi
Regeneration joins rod-side flow to pump flow at the cap port.

Anatomy

Double-acting cylinder cutaway
Double-acting cylinder cutawayPUSH FORCE113klbfPULL FORCE62.8klbfEXTEND SPEED2.042in/sCYCLE TIME15.23sPumpCap chamberRod chamberPressureReturnTank / suctionTrapped rod pressure / rating144%0%100% reference150%

Results

US customary

Ideal trapped rod-side pressure exceeds the entered rod-side rating. Review isolation, port relief and the full pressure path.

Standard push force113,097.336lbf
Pull force62,831.853lbf
Regenerative push force50,265.482lbf
Standard extend speed2.042in/s51.879mm/s
Regenerative extend speed4.596in/s116.728mm/s
Retract speed3.676in/s93.383mm/s
Selected extend + retract15.232s
Standard cycle time15.232s
Regenerative cycle time9.792s
Ideal trapped rod pressure7,200psi
Cap area28.274in²
Rod-side annulus area15.708in²
Cap-to-annulus area ratio1.8:1
2:1 area checkOutside 2.5% of 2:1

Worked calculation

  1. Piston areas

    A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.

  2. Force and speed

    Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.

  3. Cycle time and equal speeds

    Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.

  4. Trapped pressure

    P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.

Results for the original example inputs
Cap area28.274in²
Rod-side annulus area15.708in²
Standard push force113,097.336lbf
Regenerative push force50,265.482lbf
Selected extend + retract15.232s
Ideal trapped rod pressure7,200psi

Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.