Worked example

Large-rod intensification check

A rod near the bore diameter creates a small annulus. The resulting static pressure multiplication can exceed common hose and port ratings.

Inputs

in
in
in
psi
GPM
psi
Regeneration joins rod-side flow to pump flow at the cap port.

Anatomy

Double-acting cylinder cutaway
Double-acting cylinder cutawayPUSH FORCE28.9klbfPULL FORCE9822lbfEXTEND SPEED2.451in/sCYCLE TIME8.746sPumpCap chamberRod chamberPressureReturnTank / suctionTrapped rod pressure / rating135.4%0%100% reference150%

Results

US customary

Ideal trapped rod-side pressure exceeds the entered rod-side rating. Review isolation, port relief and the full pressure path.

Standard push force28,902.652lbf
Pull force9,822.386lbf
Regenerative push force19,080.267lbf
Standard extend speed2.451in/s62.255mm/s
Regenerative extend speed3.713in/s94.304mm/s
Retract speed7.212in/s183.187mm/s
Selected extend + retract8.746s
Standard cycle time8.746s
Regenerative cycle time6.528s
Ideal trapped rod pressure6,767.816psi
Cap area12.566in²
Rod-side annulus area4.271in²
Cap-to-annulus area ratio2.943:1
2:1 area checkOutside 2.5% of 2:1

Worked calculation

  1. Piston areas

    A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.

  2. Force and speed

    Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.

  3. Cycle time and equal speeds

    Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.

  4. Trapped pressure

    P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.

Results for the original example inputs
Cap area12.566in²
Rod-side annulus area4.271in²
Standard push force28,902.652lbf
Regenerative push force19,080.267lbf
Selected extend + retract8.746s
Ideal trapped rod pressure6,767.816psi

Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.