Worked example

Cold ISO VG 68 oil in a measured bore

Enter 200 cSt at the selected cold condition and use the measured 0.62-inch ID. The oil stays laminar while the pressure gradient rises.

Inputs

GPM
Selecting a grade loads its nominal 40 °C viscosity.
cSt
Replace the grade value with viscosity at the actual oil temperature.
Use actual hose or tube ID for a specific product.
in

Anatomy

Hose cross-section and service velocity
Hose cross-section and service velocityINSIDE DIA.0.62inOIL VELOCITY11.69ft/sREYNOLDS280.5LOSS / LENGTH3.577psi/ftOil pathMeasured inside diameterCross-sectionInside diameterPressureReturnTank / suctionOil velocity / service limit46.76%0%100% reference150%

Results

US customary

Oil velocity is below the typical band for this service. Check routing, cold-start behavior and available hose sizes.

Selected inside diameter0.62in
Mean oil velocity11.69ft/s3.563m/s
Reynolds number280.549
Reynolds regimeLaminar
Darcy friction factor0.22812
Straight-line pressure loss3.577psi/ft0.8091bar/m
Typical service minimum15ft/s
Typical service maximum25ft/s
Minimum ID at velocity limit0.424in
Minimum nominal dash size-8

Worked calculation

  1. ID and velocity

    Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].

  2. Flow regime

    Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.

  3. Darcy–Weisbach

    ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.

Results for the original example inputs
Selected inside diameter0.62in
Mean oil velocity11.69ft/s
Reynolds number280.549
Reynolds regimeLaminar
Straight-line pressure loss3.577psi/ft
Minimum nominal dash size-8

Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.