Worked example
Cold ISO VG 68 oil in a measured bore
Enter 200 cSt at the selected cold condition and use the measured 0.62-inch ID. The oil stays laminar while the pressure gradient rises.
Inputs
Anatomy
Hose cross-section and service velocityResults
US customaryOil velocity is below the typical band for this service. Check routing, cold-start behavior and available hose sizes.
| Selected inside diameter | 0.62in |
|---|---|
| Mean oil velocity | 11.69ft/s3.563m/s |
| Reynolds number | 280.549 |
| Reynolds regime | Laminar |
| Darcy friction factor | 0.22812 |
| Straight-line pressure loss | 3.577psi/ft0.8091bar/m |
| Typical service minimum | 15ft/s |
| Typical service maximum | 25ft/s |
| Minimum ID at velocity limit | 0.424in |
| Minimum nominal dash size | -8 |
Worked calculation
ID and velocity
Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].
Flow regime
Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.
Darcy–Weisbach
ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.
| Selected inside diameter | 0.62in |
|---|---|
| Mean oil velocity | 11.69ft/s |
| Reynolds number | 280.549 |
| Reynolds regime | Laminar |
| Straight-line pressure loss | 3.577psi/ft |
| Minimum nominal dash size | -8 |
Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.