Worked example
-32 pump suction line at 25 GPM
The 2-inch bore reduces inlet velocity. Compare with the 4 ft/s planning ceiling and check cold-start inlet pressure separately.
Inputs
Anatomy
Hose cross-section and service velocityResults
US customary| Selected inside diameter | 2in |
|---|---|
| Mean oil velocity | 2.553ft/s0.778m/s |
| Reynolds number | 581.352 |
| Reynolds regime | Laminar |
| Darcy friction factor | 0.11009 |
| Straight-line pressure loss | 0.0255psi/ft0.0058bar/m |
| Typical service minimum | 2ft/s |
| Typical service maximum | 4ft/s |
| Minimum ID at velocity limit | 1.5978in |
| Minimum nominal dash size | -32 |
Worked calculation
ID and velocity
Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].
Flow regime
Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.
Darcy–Weisbach
ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.
| Selected inside diameter | 2in |
|---|---|
| Mean oil velocity | 2.553ft/s |
| Reynolds number | 581.352 |
| Reynolds regime | Laminar |
| Straight-line pressure loss | 0.0255psi/ft |
| Minimum nominal dash size | -32 |
Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.