Worked example

-32 pump suction line at 25 GPM

The 2-inch bore reduces inlet velocity. Compare with the 4 ft/s planning ceiling and check cold-start inlet pressure separately.

Inputs

GPM
Selecting a grade loads its nominal 40 °C viscosity.
cSt
Replace the grade value with viscosity at the actual oil temperature.
Use actual hose or tube ID for a specific product.

Anatomy

Hose cross-section and service velocity
Hose cross-section and service velocityINSIDE DIA.2inOIL VELOCITY2.553ft/sREYNOLDS581.4LOSS / LENGTH0.02553psi/ftOil pathNominal dash boreCross-sectionInside diameterPressureReturnTank / suctionOil velocity / service limit63.83%0%100% reference150%

Results

US customary
Selected inside diameter2in
Mean oil velocity2.553ft/s0.778m/s
Reynolds number581.352
Reynolds regimeLaminar
Darcy friction factor0.11009
Straight-line pressure loss0.0255psi/ft0.0058bar/m
Typical service minimum2ft/s
Typical service maximum4ft/s
Minimum ID at velocity limit1.5978in
Minimum nominal dash size-32

Worked calculation

  1. ID and velocity

    Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].

  2. Flow regime

    Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.

  3. Darcy–Weisbach

    ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.

Results for the original example inputs
Selected inside diameter2in
Mean oil velocity2.553ft/s
Reynolds number581.352
Reynolds regimeLaminar
Straight-line pressure loss0.0255psi/ft
Minimum nominal dash size-32

Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.