Worked example

Conveyor motor at part load

The motor sees 1,100 psi differential across its ports. Use that differential for torque even if pump gauge pressure is higher.

Inputs

in³/rev
psi
Inlet pressure minus outlet pressure.
GPM
%
%
RPM
%
Percentage of running torque for this estimate. Use OEM breakaway data when available.

Anatomy

Motor torque versus differential pressure
Motor torque versus differential pressureSHAFT SPEED237.2RPMRUN TORQUE150.6lb-ftSTART TORQUE120.4lb-ftSHAFT POWER6.799HPOil motorShaftTorque795.8 lb-ftDifferential pressurePressureReturnTank / suctionShaft speed / entered rating31.62%0%100% reference150%

Results

US customary

Starting torque uses the entered estimate factor. Verify breakaway torque and allowable speed against the motor’s performance data.

Actual shaft speed237.16RPM
Theoretical shaft speed269.5RPM
Theoretical torque175.07lb-ft
Running torque150.561lb-ft204.133N·m
Estimated starting torque120.448lb-ft
Shaft output power6.799HP5.07kW
Hydraulic input power8.983HP
Overall efficiency75.68%

Worked calculation

  1. Shaft speed

    RPM = 60 × Q × η_v/D when Q is in m³/s and D is in m³/rev.

  2. Running and starting torque

    Ideal torque = ΔP × D/(2π). Running torque = ideal torque × η_m. Starting estimate = running torque × the entered start factor.

  3. Shaft power

    P = T × 2π × RPM/60. In US units, HP ≈ torque (lb-ft) × RPM/5252.

Results for the original example inputs
Theoretical shaft speed269.5RPM
Actual shaft speed237.16RPM
Theoretical torque175.07lb-ft
Running torque150.561lb-ft
Estimated starting torque120.448lb-ft
Shaft output power6.799HP

Steady-point estimate using constant efficiencies. Verify intermittent versus continuous pressure, minimum speed, breakaway torque and case-drain limits with the OEM.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.