Worked example

Small-displacement high-speed motor

A smaller displacement gives higher RPM at the same flow and less torque at the same pressure difference.

Inputs

in³/rev
psi
Inlet pressure minus outlet pressure.
GPM
%
%
RPM
%
Percentage of running torque for this estimate. Use OEM breakaway data when available.

Anatomy

Motor torque versus differential pressure
Motor torque versus differential pressureSHAFT SPEED1448RPMRUN TORQUE42.49lb-ftSTART TORQUE34.85lb-ftSHAFT POWER11.71HPOil motorShaftTorque99.47 lb-ftDifferential pressurePressureReturnTank / suctionShaft speed / entered rating80.42%0%100% reference150%

Results

US customary

Starting torque uses the entered estimate factor. Verify breakaway torque and allowable speed against the motor’s performance data.

Actual shaft speed1,447.6RPM
Theoretical shaft speed1,540RPM
Theoretical torque47.746lb-ft
Running torque42.494lb-ft57.615N·m
Estimated starting torque34.845lb-ft
Shaft output power11.712HP8.734kW
Hydraulic input power14HP
Overall efficiency83.66%

Worked calculation

  1. Shaft speed

    RPM = 60 × Q × η_v/D when Q is in m³/s and D is in m³/rev.

  2. Running and starting torque

    Ideal torque = ΔP × D/(2π). Running torque = ideal torque × η_m. Starting estimate = running torque × the entered start factor.

  3. Shaft power

    P = T × 2π × RPM/60. In US units, HP ≈ torque (lb-ft) × RPM/5252.

Results for the original example inputs
Theoretical shaft speed1,540RPM
Actual shaft speed1,447.6RPM
Theoretical torque47.746lb-ft
Running torque42.494lb-ft
Estimated starting torque34.845lb-ft
Shaft output power11.712HP

Steady-point estimate using constant efficiencies. Verify intermittent versus continuous pressure, minimum speed, breakaway torque and case-drain limits with the OEM.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.