Worked example

Reservoir for a 42 GPM pump

The 3–5 minute guide scales reservoir volume directly with flow. The thermal duty also depends on surface area, efficiency and temperatures.

Inputs

HP
%
Useful power divided by shaft input over the duty cycle.
GPM
°F
°F
ft²
BTU/hr·ft²·°F
Typical bare-steel starting estimate is 2–2.5 BTU/hr·ft²·°F.
°F
Oil inlet temperature minus coolant inlet temperature at the cooler.

Anatomy

Hydraulic power unit thermal balance
Hydraulic power unit thermal balanceCIRCUIT HEAT26.7kBTU/hrTANK HEAT6240BTU/hrCOOLER LOAD20.5kBTU/hrMIN. TANK126galPumpLoadCoolerReservoirTank heatPressureReturnTank / suctionCooler load / circuit heat76.64%0%100% reference150%

Results

US customary
Circuit heat generation26,716.553BTU/hr7.83kW
Oil target minus ambient52°F
Passive tank rejection6,240BTU/hr1.829kW
Required cooler heat removal20,476.553BTU/hr6.001kW
Net heat · horsepower equivalent8.048HP6.001kW
Cooler rating at entered ETD426.5948BTU/hr/°F0.225kW/°C
Reservoir guide · 3 min126gal
Reservoir guide · 5 min210gal

Worked calculation

  1. Heat generation

    Heat in = shaft input × (1 − duty-weighted efficiency). Use average shaft power across the same duty cycle.

  2. Reservoir heat rejection

    Tank heat out = h × exposed area × (T_oil − T_ambient). A negative result means the surroundings add heat.

  3. Cooler capacity and reservoir volume

    Cooler load = max(0, heat in − tank heat out). Required cooler rating = load/ETD. The 3–5 minute volume guide is 3–5 gal per GPM or 3–5 L per LPM.

Results for the original example inputs
Circuit heat generation26,716.553BTU/hr
Passive tank rejection6,240BTU/hr
Required cooler heat removal20,476.553BTU/hr
Cooler rating at entered ETD426.5948BTU/hr/°F
Reservoir guide · 3 min126gal
Reservoir guide · 5 min210gal