Worked example

Large tank with passive rejection

At low circuit loss and a large exposed tank, calculated passive rejection exceeds generated heat at the oil target.

Inputs

HP
%
Useful power divided by shaft input over the duty cycle.
GPM
°F
°F
ft²
BTU/hr·ft²·°F
Typical bare-steel starting estimate is 2–2.5 BTU/hr·ft²·°F.
°F
Oil inlet temperature minus coolant inlet temperature at the cooler.

Anatomy

Hydraulic power unit thermal balance
Hydraulic power unit thermal balanceCIRCUIT HEAT2544BTU/hrTANK HEAT8262BTU/hrCOOLER LOAD0BTU/hrMIN. TANK24galPumpLoadCoolerReservoirTank heatPressureReturnTank / suctionCooler load / circuit heat0%0%100% reference150%

Results

US customary
Circuit heat generation2,544.434BTU/hr0.746kW
Oil target minus ambient68°F
Passive tank rejection8,262BTU/hr2.421kW
Required cooler heat removal0BTU/hr0kW
Net heat · horsepower equivalent0HP0kW
Cooler rating at entered ETD0BTU/hr/°F0kW/°C
Reservoir guide · 3 min24gal
Reservoir guide · 5 min40gal

Worked calculation

  1. Heat generation

    Heat in = shaft input × (1 − duty-weighted efficiency). Use average shaft power across the same duty cycle.

  2. Reservoir heat rejection

    Tank heat out = h × exposed area × (T_oil − T_ambient). A negative result means the surroundings add heat.

  3. Cooler capacity and reservoir volume

    Cooler load = max(0, heat in − tank heat out). Required cooler rating = load/ETD. The 3–5 minute volume guide is 3–5 gal per GPM or 3–5 L per LPM.

Results for the original example inputs
Circuit heat generation2,544.434BTU/hr
Passive tank rejection8,262BTU/hr
Required cooler heat removal0BTU/hr
Cooler rating at entered ETD0BTU/hr/°F
Reservoir guide · 3 min24gal
Reservoir guide · 5 min40gal

Steady thermal balance at the entered target oil temperature. OEM cooler ratings depend on oil viscosity, coolant and oil flow, fan airflow, fouling and allowable pressure drop. Size tank working volume for deaeration, return levels and cylinder drawdown.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.