Worked example

Size an orifice for 14 GPM

With a 300 psi differential budget, solve the equivalent round opening. Select the actual valve using its tested flow curve.

Inputs

psi
GPM
A typical sharp-edged sizing range is 0.61–0.82.
Many mineral hydraulic oils are around 0.85–0.88.
psi
Enter the project’s differential-pressure check value.

Anatomy

Restriction and oil flow versus pressure drop
Restriction and oil flow versus pressure dropOIL FLOW14GPMPRESS. DROP300psiORIFICE ID0.189inVALVE LOSS2.45HPOrifice plateUpstreamDownstreamFlow rate18.96 GPMPressure dropPressureReturnTank / suctionPressure drop / review limit54.55%0%100% reference150%

Results

US customary
Orifice flow rate14GPM52.996LPM
Pressure drop ΔP300psi20.684bar
Equivalent orifice diameter0.189in
Mean orifice velocity160.14ft/s48.811m/s
Throttling power loss2.45HP1.827kW
Equivalent oil heat6,233.862BTU/hr

Worked calculation

  1. Turbulent orifice flow

    Q_gpm = 29.81 × Cd × d_in² × √(ΔP_psi/SG). Q_lpm ≈ 0.6661 × Cd × d_mm² × √(ΔP_bar/SG). The SI factor is converted from the same US expression.

  2. Solving for size or drop

    ΔP = SG × [Q/(K × Cd × d²)]². d = √[Q/(K × Cd × √(ΔP/SG))]. Use the matching unit-system constant K.

  3. Jet velocity and heat

    Mean velocity = Q/(πd²/4). Throttling loss = ΔP × Q. Under steady dissipation this loss becomes heat.

Results for the original example inputs
Equivalent orifice diameter0.189in
Pressure drop ΔP300psi
Orifice flow rate14GPM
Mean orifice velocity160.14ft/s
Throttling power loss2.45HP

Models a steady incompressible, turbulent sharp-edged restriction with a fixed discharge coefficient. Use valve OEM flow curves and check cavitation, jet erosion and minimum downstream pressure.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.