Hydraulic Pump Horsepower & Displacement Calculator
Calculate actual flow, prime-mover power and pump heat from shaft speed, discharge pressure and volumetric and mechanical efficiency.
Inputs
Anatomy
Positive-displacement pump power balanceResults
US customary| Actual outlet flow | 13.939GPM |
|---|---|
| Theoretical flow | 15.152GPM |
| Pump displacement | 2in³/rev |
| Hydraulic output power | 20.328HP15.159kW |
| Required shaft power | 24.551HP18.308kW |
| Pump waste heat | 10,744.592BTU/hr3.149kW |
| Volumetric loss | 4,497.736BTU/hr |
| Mechanical loss | 6,246.856BTU/hr |
| Overall efficiency | 82.8% |
Formulas and assumptions
Flow and displacement
Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).
Prime-mover power
P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).
Pump heat
Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.
Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.