Worked example

Low-flow pump at 5,000 psi

Small displacement limits flow. High pressure still produces substantial shaft torque and heat from the pump losses.

Inputs

RPM
in³/rev
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW2.802GPMSHAFT INPUT10.67HPOIL OUTPUT8.173HPWASTE HEAT6367BTU/hrMPrime mover1200 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling100%0%100% reference150%

Results

US customary
Actual outlet flow2.802GPM
Theoretical flow3.221GPM
Pump displacement0.62in³/rev
Hydraulic output power8.173HP6.094kW
Required shaft power10.675HP7.96kW
Pump waste heat6,366.692BTU/hr1.866kW
Volumetric loss3,107.293BTU/hr
Mechanical loss3,259.398BTU/hr
Overall efficiency76.56%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement0.62in³/rev
Theoretical flow3.221GPM
Actual outlet flow2.802GPM
Overall efficiency76.56%
Required shaft power10.675HP
Pump waste heat6,366.692BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.