Worked example

Pump with increased leakage

At 80% volumetric efficiency the leakage loss grows. The mechanical loss follows its own efficiency and theoretical power.

Inputs

RPM
in³/rev
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW12.12GPMSHAFT INPUT24.55HPOIL OUTPUT17.68HPWASTE HEAT17.5kBTU/hrMPrime mover1750 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling50%0%100% reference150%

Results

US customary
Actual outlet flow12.121GPM
Theoretical flow15.152GPM
Pump displacement2in³/rev
Hydraulic output power17.677HP13.182kW
Required shaft power24.551HP18.308kW
Pump waste heat17,491.196BTU/hr5.126kW
Volumetric loss11,244.34BTU/hr
Mechanical loss6,246.856BTU/hr
Overall efficiency72%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement2in³/rev
Theoretical flow15.152GPM
Actual outlet flow12.121GPM
Overall efficiency72%
Required shaft power24.551HP
Pump waste heat17,491.196BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.