Worked example

Size a pump for 20 GPM

Divide target outlet flow by volumetric efficiency first. The theoretical flow and shaft RPM determine the displacement to look for.

Inputs

RPM
GPM
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW20GPMSHAFT INPUT44.19HPOIL OUTPUT35HPWASTE HEAT23.4kBTU/hrMPrime mover1750 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling60%0%100% reference150%

Results

US customary
Actual outlet flow20GPM
Theoretical flow22.222GPM
Pump displacement2.933in³/rev
Hydraulic output power35HP26.099kW
Required shaft power44.192HP32.954kW
Pump waste heat23,388.228BTU/hr6.854kW
Volumetric loss9,895.019BTU/hr
Mechanical loss13,493.208BTU/hr
Overall efficiency79.2%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement2.933in³/rev
Theoretical flow22.222GPM
Actual outlet flow20GPM
Overall efficiency79.2%
Required shaft power44.192HP
Pump waste heat23,388.228BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.