Worked example

2 in³/rev pump at 1,750 RPM

Multiply displacement by speed to get theoretical flow. Volumetric leakage reduces outlet flow, while leakage and mechanical loss both increase shaft demand.

Inputs

RPM
in³/rev
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW13.94GPMSHAFT INPUT24.55HPOIL OUTPUT20.33HPWASTE HEAT10.7kBTU/hrMPrime mover1750 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling50%0%100% reference150%

Results

US customary
Actual outlet flow13.939GPM
Theoretical flow15.152GPM
Pump displacement2in³/rev
Hydraulic output power20.328HP15.159kW
Required shaft power24.551HP18.308kW
Pump waste heat10,744.592BTU/hr3.149kW
Volumetric loss4,497.736BTU/hr
Mechanical loss6,246.856BTU/hr
Overall efficiency82.8%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement2in³/rev
Theoretical flow15.152GPM
Actual outlet flow13.939GPM
Overall efficiency82.8%
Required shaft power24.551HP
Pump waste heat10,744.592BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.