Daylight Factor Calculator

Estimate average interior daylight under a CIE overcast sky from glazing, visible sky angle, and room reflectance.

Room and window
ft
ft
ft
ft²
°
Surfaces and sky
fc
Daylight DF
4.95%
Interior avg.
45.98fc
Glazing/floor
19%
Bounding area
1,744ft²

Window and visible sky section

Edit inputs ↓
Window and visible sky sectionOVERCAST SKYWINDOW SECTIONθ 68°T 0.68Glass 84 ft²Average interior daylight45.98 fc
The sky angle is the unobstructed vertical sky seen from the glazing, measured in degrees.

Daylight adequacy

Within screen
OutsideThresholdWithin
  • Lower daylight band4.95 / ≥ 2 % within screen
  • Upper daylight band4.95 / ≤ 5 % within screen

2–5% · well-daylit screen

Additional readings
Room floor area442ft²
Total wall area860ft²
Horizontal overcast illuminance929.03fc
Daylight screening tier2–5% · well-daylit screen

Calculation method

This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².

Bounding area
Atot = 2(LW + LH + WH)
Simplified daylight factor
DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
Interior daylight and glazing ratio
Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)

Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.