Bright corner glazing

Combine generous glazing, open sky, and pale finishes to examine the upper daylight band and potential glare screen.

Room and window
ft
ft
ft
ft²
°
Surfaces and sky
fc
Daylight DF
41.98%
Interior avg.
409.48fc
Glazing/floor
73.16%
Bounding area
1,190.1ft²

Window and visible sky section

Edit inputs ↓
Window and visible sky sectionOVERCAST SKYWINDOW SECTIONθ 85°T 0.78Glass 188.37 ft²Average interior daylight409.48 fc
The sky angle is the unobstructed vertical sky seen from the glazing, measured in degrees.

Daylight adequacy

Review needed
OutsideThresholdWithin
  • Lower daylight band41.98 / ≥ 2 % within screen
  • Upper daylight band41.98 / ≤ 5 % outside screen

Above 5% · glare risk screen

Additional readings
Room floor area257.47ft²
Total wall area675.11ft²
Horizontal overcast illuminance975.48fc
Daylight screening tierAbove 5% · glare risk screen

Worked calculation

US customary results for the original preset.

  1. Add the floor, ceiling, and four walls to get a bounding surface area of 1190.1 ft².
  2. Combine 188.37 ft² of glazing, transmittance 0.78, and 85 ° of visible sky. The simplified DF is 41.98 %.
  3. Multiply 975.48 fc outside by DF/100 to get 409.48 fc average inside. The window-to-floor ratio is 73.16 %.

Calculation method

This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².

Bounding area
Atot = 2(LW + LH + WH)
Simplified daylight factor
DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
Interior daylight and glazing ratio
Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)

Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.

Sources and assumptions ↗