Fully obstructed window
Set the visible sky angle to zero. The model gives zero direct overcast daylight even though the room still has a nonzero glazing-to-floor ratio.
Inputs
View results ↑- Daylight DF
- 0%
- Interior avg.
- 0fc
- Glazing/floor
- 24.24%
- Bounding area
- 1,211.4ft²
Window and visible sky section
Edit inputs ↓Daylight adequacy
Review neededOutsideThresholdWithin
- Lower daylight band0 / ≥ 2 % outside screen
- Upper daylight band0 / ≤ 5 % within screen
Below 2% · low daylight
Additional readings
| Room floor area | 284.17ft² |
|---|---|
| Total wall area | 643.04ft² |
| Horizontal overcast illuminance | 1,021.93fc |
| Daylight screening tier | Below 2% · low daylight |
Worked calculation
US customary results for the original preset.
- Add the floor, ceiling, and four walls to get a bounding surface area of 1211.4 ft².
- Combine 68.89 ft² of glazing, transmittance 0.64, and 0 ° of visible sky. The simplified DF is 0 %.
- Multiply 1021.93 fc outside by DF/100 to get 0 fc average inside. The window-to-floor ratio is 24.24 %.
Calculation method
This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².
- Bounding area
- Atot = 2(LW + LH + WH)
- Simplified daylight factor
- DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
- Interior daylight and glazing ratio
- Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.
Sources and assumptions ↗LightingLuxLab · US customary
Fully obstructed window
Inputs
| Room length | 18.0446194ft |
|---|---|
| Room width | 15.7480315ft |
| Room height | 9.5144357ft |
| Net glazed area | 68.8890267ft² |
| Visible transmittance | 0.64 |
| Visible sky angle | 0° |
| Mean surface reflectance | 0.54 |
| Outdoor overcast illuminance | 1,021.93344fc |
Results
| Daylight DF | 0% |
|---|---|
| Interior avg. | 0fc |
| Glazing/floor | 24.24% |
| Bounding area | 1,211.4ft² |
| Room floor area | 284.17ft² |
| Total wall area | 643.04ft² |
| Horizontal overcast illuminance | 1,021.93fc |
| Daylight screening tier | Below 2% · low daylight |
Daylight adequacy
- Lower daylight band · 0 / ≥ 2 % · Outside screen
- Upper daylight band · 0 / ≤ 5 % · Within screen
Below 2% · low daylight
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.