Fully obstructed window

Set the visible sky angle to zero. The model gives zero direct overcast daylight even though the room still has a nonzero glazing-to-floor ratio.

Room and window
ft
ft
ft
ft²
°
Surfaces and sky
fc
Daylight DF
0%
Interior avg.
0fc
Glazing/floor
24.24%
Bounding area
1,211.4ft²

Window and visible sky section

Edit inputs ↓
Window and visible sky sectionOVERCAST SKYWINDOW SECTIONθ 0°T 0.64Glass 68.89 ft²Average interior daylight0 fc
The sky angle is the unobstructed vertical sky seen from the glazing, measured in degrees.

Daylight adequacy

Review needed
OutsideThresholdWithin
  • Lower daylight band0 / ≥ 2 % outside screen
  • Upper daylight band0 / ≤ 5 % within screen

Below 2% · low daylight

Additional readings
Room floor area284.17ft²
Total wall area643.04ft²
Horizontal overcast illuminance1,021.93fc
Daylight screening tierBelow 2% · low daylight

Worked calculation

US customary results for the original preset.

  1. Add the floor, ceiling, and four walls to get a bounding surface area of 1211.4 ft².
  2. Combine 68.89 ft² of glazing, transmittance 0.64, and 0 ° of visible sky. The simplified DF is 0 %.
  3. Multiply 1021.93 fc outside by DF/100 to get 0 fc average inside. The window-to-floor ratio is 24.24 %.

Calculation method

This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².

Bounding area
Atot = 2(LW + LH + WH)
Simplified daylight factor
DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
Interior daylight and glazing ratio
Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)

Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.

Sources and assumptions ↗