Bright corner glazing
Combine generous glazing, open sky, and pale finishes to examine the upper daylight band and potential glare screen.
Inputs
View results ↑- Daylight DF
- 41.98%
- Interior avg.
- 409.48fc
- Glazing/floor
- 73.16%
- Bounding area
- 1,190.1ft²
Window and visible sky section
Edit inputs ↓Daylight adequacy
Review neededOutsideThresholdWithin
- Lower daylight band41.98 / ≥ 2 % within screen
- Upper daylight band41.98 / ≤ 5 % outside screen
Above 5% · glare risk screen
Additional readings
| Room floor area | 257.47ft² |
|---|---|
| Total wall area | 675.11ft² |
| Horizontal overcast illuminance | 975.48fc |
| Daylight screening tier | Above 5% · glare risk screen |
Worked calculation
US customary results for the original preset.
- Add the floor, ceiling, and four walls to get a bounding surface area of 1190.1 ft².
- Combine 188.37 ft² of glazing, transmittance 0.78, and 85 ° of visible sky. The simplified DF is 41.98 %.
- Multiply 975.48 fc outside by DF/100 to get 409.48 fc average inside. The window-to-floor ratio is 73.16 %.
Calculation method
This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².
- Bounding area
- Atot = 2(LW + LH + WH)
- Simplified daylight factor
- DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
- Interior daylight and glazing ratio
- Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.
Sources and assumptions ↗LightingLuxLab · US customary
Bright corner glazing
Inputs
| Room length | 17.0603675ft |
|---|---|
| Room width | 15.0918635ft |
| Room height | 10.4986877ft |
| Net glazed area | 188.3684323ft² |
| Visible transmittance | 0.78 |
| Visible sky angle | 85° |
| Mean surface reflectance | 0.75 |
| Outdoor overcast illuminance | 975.48192fc |
Results
| Daylight DF | 41.98% |
|---|---|
| Interior avg. | 409.48fc |
| Glazing/floor | 73.16% |
| Bounding area | 1,190.1ft² |
| Room floor area | 257.47ft² |
| Total wall area | 675.11ft² |
| Horizontal overcast illuminance | 975.48fc |
| Daylight screening tier | Above 5% · glare risk screen |
Daylight adequacy
- Lower daylight band · 41.98 / ≥ 2 % · Within screen
- Upper daylight band · 41.98 / ≤ 5 % · Outside screen
Above 5% · glare risk screen
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.