Directly below a downlight

Use on-axis intensity with zero horizontal offset. The horizontal result follows the inverse-square law, and the radial vertical contribution is zero.

Primary ray
cd
ft
ft
ft
Pair and target
ft
Zero uses the primary position only. The second source is at x = spacing.
fc
Horizontal
19.55fc
Radial vert.
0fc
Nadir angle
0°
Slant distance
9.19ft

Inverse-square ray geometry

Edit inputs ↓
Inverse-square ray geometryRAY SECTIONONE POSITIONh 9.19 ftθ 0°r 0 ftD 9.19 ftHorizontal light19.55 fc
The ray section folds the x and y offsets into radial distance. Vertical readings are radially facing magnitudes.

Horizontal task target

Within screen
OutsideThresholdWithin
  • Direct horizontal light19.55 / ≥ 18.58 fc within screen

Choose a task and a project target appropriate to its IES recommendation.

Additional readings
Primary radial offset0ft
Primary horizontal contribution19.55fc
Primary radial vertical contribution0fc
Second nadir angle—
Second slant distance—
Second horizontal contribution—
Second radial vertical contribution—

Worked calculation

US customary results for the original preset.

  1. Combine the two offsets to get a radius of 0 ft. The primary slant distance is 9.19 ft at 0 °.
  2. Project 1650 cd onto the horizontal plane. The primary group contributes 19.55 fc.
  3. Use the primary group alone. The radial-facing vertical total is 0 fc.

Calculation method

Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.

Distance and angle
r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
Horizontal and radial vertical light
Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
Superposition
Etotal = m × sum of illuminances at the modeled positions

This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.

Sources and assumptions ↗