Gallery wall at an offset

Compare horizontal and radial-facing vertical light at a point displaced both along and across the gallery.

Primary ray
cd
ft
ft
ft
Pair and target
ft
Zero uses the primary position only. The second source is at x = spacing.
fc
Horizontal
10.6fc
Radial vert.
6.58fc
Nadir angle
31.8°
Slant distance
13.13ft

Inverse-square ray geometry

Edit inputs ↓
Inverse-square ray geometryRAY SECTIONONE POSITIONh 11.15 ftθ 31.8°r 6.92 ftD 13.13 ftHorizontal light10.6 fc
The ray section folds the x and y offsets into radial distance. Vertical readings are radially facing magnitudes.

Horizontal task target

Review needed
OutsideThresholdWithin
  • Direct horizontal light10.6 / ≥ 13.94 fc outside screen

Choose a task and a project target appropriate to its IES recommendation.

Additional readings
Primary radial offset6.92ft
Primary horizontal contribution10.6fc
Primary radial vertical contribution6.58fc
Second nadir angle—
Second slant distance—
Second horizontal contribution—
Second radial vertical contribution—

Worked calculation

US customary results for the original preset.

  1. Combine the two offsets to get a radius of 6.92 ft. The primary slant distance is 13.13 ft at 31.8 °.
  2. Project 2150 cd onto the horizontal plane. The primary group contributes 10.6 fc.
  3. Use the primary group alone. The radial-facing vertical total is 6.58 fc.

Calculation method

Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.

Distance and angle
r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
Horizontal and radial vertical light
Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
Superposition
Etotal = m × sum of illuminances at the modeled positions

This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.

Sources and assumptions ↗