Gallery wall at an offset
Compare horizontal and radial-facing vertical light at a point displaced both along and across the gallery.
Inputs
View results ↑- Horizontal
- 10.6fc
- Radial vert.
- 6.58fc
- Nadir angle
- 31.8°
- Slant distance
- 13.13ft
Inverse-square ray geometry
Edit inputs ↓Horizontal task target
Review neededOutsideThresholdWithin
- Direct horizontal light10.6 / ≥ 13.94 fc outside screen
Choose a task and a project target appropriate to its IES recommendation.
Additional readings
| Primary radial offset | 6.92ft |
|---|---|
| Primary horizontal contribution | 10.6fc |
| Primary radial vertical contribution | 6.58fc |
| Second nadir angle | — |
| Second slant distance | — |
| Second horizontal contribution | — |
| Second radial vertical contribution | — |
Worked calculation
US customary results for the original preset.
- Combine the two offsets to get a radius of 6.92 ft. The primary slant distance is 13.13 ft at 31.8 °.
- Project 2150 cd onto the horizontal plane. The primary group contributes 10.6 fc.
- Use the primary group alone. The radial-facing vertical total is 6.58 fc.
Calculation method
Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.
- Distance and angle
- r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
- Horizontal and radial vertical light
- Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
- Superposition
- Etotal = m × sum of illuminances at the modeled positions
This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.
Sources and assumptions ↗LightingLuxLab · US customary
Gallery wall at an offset
Inputs
| Directional intensity | 2,150cd |
|---|---|
| Mounting height above point | 11.1548556ft |
| Longitudinal offset | 3.6089239ft |
| Crosswise offset | 5.9055118ft |
| Luminaires per position | 1 |
| Second position spacing | 0ft |
| Horizontal target | 13.935456fc |
Results
| Horizontal | 10.6fc |
|---|---|
| Radial vert. | 6.58fc |
| Nadir angle | 31.8° |
| Slant distance | 13.13ft |
| Primary radial offset | 6.92ft |
| Primary horizontal contribution | 10.6fc |
| Primary radial vertical contribution | 6.58fc |
| Second nadir angle | — |
| Second slant distance | — |
| Second horizontal contribution | — |
| Second radial vertical contribution | — |
Horizontal task target
- Direct horizontal light · 10.6 / ≥ 13.94 fc · Outside screen
Choose a task and a project target appropriate to its IES recommendation.
This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.