Point-by-Point Illuminance
Project directional candela onto horizontal and vertical receiving planes, with an optional second source group.
Inputs
View results ↑- Horizontal
- 16.01fc
- Radial vert.
- 11.54fc
- Nadir angle
- 35.8°
- Slant distance
- 12.33ft
Inverse-square ray geometry
Edit inputs ↓Horizontal task target
Within screenOutsideThresholdWithin
- Direct horizontal light16.01 / ≥ 15 fc within screen
Choose a task and a project target appropriate to its IES recommendation.
Additional readings
| Primary radial offset | 7.21ft |
|---|---|
| Primary horizontal contribution | 16.01fc |
| Primary radial vertical contribution | 11.54fc |
| Second nadir angle | — |
| Second slant distance | — |
| Second horizontal contribution | — |
| Second radial vertical contribution | — |
Calculation method
Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.
- Distance and angle
- r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
- Horizontal and radial vertical light
- Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
- Superposition
- Etotal = m × sum of illuminances at the modeled positions
This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.
Sources and assumptions ↗LightingLuxLab · US customary
Point-by-Point Illuminance
Inputs
| Directional intensity | 3,000cd |
|---|---|
| Mounting height above point | 10ft |
| Longitudinal offset | 6ft |
| Crosswise offset | 4ft |
| Luminaires per position | 1 |
| Second position spacing | 0ft |
| Horizontal target | 15fc |
Results
| Horizontal | 16.01fc |
|---|---|
| Radial vert. | 11.54fc |
| Nadir angle | 35.8° |
| Slant distance | 12.33ft |
| Primary radial offset | 7.21ft |
| Primary horizontal contribution | 16.01fc |
| Primary radial vertical contribution | 11.54fc |
| Second nadir angle | — |
| Second slant distance | — |
| Second horizontal contribution | — |
| Second radial vertical contribution | — |
Horizontal task target
- Direct horizontal light · 16.01 / ≥ 15 fc · Within screen
Choose a task and a project target appropriate to its IES recommendation.
This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.