Positive-slope module bound

Screen a module with a positive entered voltage slope. The hot limit leads the driver voltage and heat bounds rather than cold start.

Constant-current driver
V
Nominal value at 25 °C / 77 °F.
mV/°F
A
V
Ambient and thermal path
°F
°F
°F/W
°F/W
°F/W
°F
Cold string
29.92V
AC input
60.1W
Junction
185°F
Thermal margin
45°F

Driver and thermal stack

Edit inputs ↓
Driver and thermal stackCONSTANT CURRENTTHERMAL STACKJunction185 °FCase178.9 °FHeat sink177.2 °FAmbient131 °FCC DRIVER10S × 3PCold-start string voltage29.92 V
The package and interface carry one module’s heat. A shared sink carries the heat from every module.

Driver and thermal limits

Within screen
OutsideThresholdWithin
  • Driver voltage31.42 / ≤ 33 V within screen
  • Junction rise above ambient54 / ≤ 99 °F within screen

Heat uses the larger modeled forward drop at maximum ambient or the junction limit. This bounds heat while the junction stays within the selected limit.

Additional readings
Nominal string voltage30.4V
Cold-start driver headroom3.08V
Highest screened string voltage31.42V
Driver margin over screened range1.58V
Nominal electrical power per string18.24W
Nominal DC load, all strings54.72W
Cold-start AC estimate at nominal efficiency59.18W
Estimated heat per LED1.36W
Heat sink temperature177.2°F
LED case temperature178.9°F
Effective module-to-ambient resistance39.78°F/W

Worked calculation

US customary results for the original preset.

  1. Apply the forward-voltage slope at 5 °F to get a cold string voltage of 29.92 V and 3.08 V of cold-start headroom.
  2. The nominal DC load is 54.7 W. At the entered efficiency, the estimated AC input is 60.1 W.
  3. Multiply 1.36 W per LED by the effective thermal resistance, then add maximum ambient to get 185 °F.

Calculation method

Use the data-sheet forward voltage at rated current, including bin tolerances where known. Select the heat sink arrangement that matches the luminaire.

Voltage and nominal power
Vf(T) = Vf,25 + β(T − 25 °C) · PDC = Ns × Np × If × Vf,25
Heat generated per LED
Pheat = If × Vf,heat × (1 − radiant fraction)
Thermal path and wall power
Tj = Ta,max + Pheat × (Rθjc + Rθcs + M × Rθsa) · PAC = PDC/η

Check current sharing, driver minimum output voltage and start-up behavior, LED bin variation, and actual assembly thermal resistance.

Sources and assumptions ↗