Zero-overhang service road
Place the optical centers on the curb line. The overhang changes the section view, with fixture flux and utilization entered independently.
Inputs
View results ↑- Pole pitch
- 108.45ft
- Pitch / height
- 4.24×
- Pole density
- 48.7poles/mi
- Linear power
- 2.39kW/km
Pole elevation and layout plan
Edit inputs ↓RP-8 layout screen
Review needed- Same-side pitch / height4.24 / ≤ 4 × outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
Additional readings
| Luminaires per repeat | 1 |
|---|---|
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 2,574.99lm |
| Area-normalized connected power | 0.027W/ft² |
| Optical overhang | 0ft |
| Distance to next pole station | 108.45ft |
| Pitch limit from height criterion | 102.36ft |
Worked calculation
US customary results for the original preset.
- Apply utilization and loss factors over 1 pole per repeat to get 2574.99 lm maintained.
- Divide by the road width and target illuminance to get 108.45 ft same-side pitch. The pitch-to-height ratio is 4.24.
- Scale the repeat to 48.7 poles/mi and 2.39 kW/km of linear connected power.
Calculation method
Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.
- Maintained lumens through one cell
- Φcell = Φ × CU × LLD × LDD × fixtures per repeat
- Same-side pole pitch
- S = Φcell/(Eavg × roadway width)
- Pole density and power
- Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.
Sources and assumptions ↗Zero-overhang service road
Inputs
| Pole configuration | Single-sided |
|---|---|
| Roadway width | 26.9028871ft |
| Mounting height | 25.5905512ft |
| Optical overhang past curb | 0ft |
| Max pitch / mounting height | 4× |
| Output per pole | 10,200lm |
| Street-side utilization | 0.33 |
| Lumen depreciation (LLD) | 0.9 |
| Dirt depreciation (LDD) | 0.85 |
| Maintained roadway target | 0.8825789fc |
| Input per pole | 79W |
Results
| Pole pitch | 108.45ft |
|---|---|
| Pitch / height | 4.24× |
| Pole density | 48.7poles/mi |
| Linear power | 2.39kW/km |
| Luminaires per repeat | 1 |
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 2,574.99lm |
| Area-normalized connected power | 0.027W/ft² |
| Optical overhang | 0ft |
| Distance to next pole station | 108.45ft |
| Pitch limit from height criterion | 102.36ft |
RP-8 layout screen
- Same-side pitch / height · 4.24 / ≤ 4 × · Outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.